改良Bentall单补片Konno扩大术治疗主动脉瓣狭窄与患者-人工瓣膜不匹配
该研究回顾了25例成人复杂左室流出道梗阻患者接受改良Bentall单补片Konno扩大术(BeSPoKE)的结果。术后所有患者植入至少21mm的人工瓣膜,平均跨瓣压差从44±19 mmHg降至8.5±4.1 mmHg(P<.001),2年生存率92%,无手术死亡。该技术可安全实现更大尺寸瓣膜植入并改善血流动力学。
要点
- BeSPoKE技术通过前室间隔心室成形术实现左室流出道扩大。
- 术后平均跨瓣压差显著降低且2年维持稳定。
- 所有生物瓣置换患者均符合未来经导管瓣膜置换条件。
核心结论
- BeSPoKE技术可安全治疗成人复杂左室流出道梗阻和患者-人工瓣膜不匹配,允许植入更大尺寸瓣膜并改善血流动力学。
主要发现
- 术前平均主动脉瓣压差为44 ± 19 mm Hg,术后降至8.5 ± 4.1 mm Hg(P < .001),2年平均压差为8.3 ± 1.3 mm Hg。
- 21例(84%)既往有主动脉瓣置换史且存在患者-人工瓣膜不匹配,术前中位植入瓣膜尺寸为19 mm;术后所有患者植入至少21 mm的瓣膜,中位增大2个尺寸(15th-85th百分位,2-3个尺寸)。
- 术后并发症包括心房颤动9例(36%)和需要置入起搏器的完全性心脏传导阻滞8例(32%);无手术死亡,无再次手术,2例晚期非心脏性死亡,2年生存率92%。
- 所有生物瓣置换患者均符合未来经导管瓣膜置换的解剖条件。
临床怎么用
- 对于小左室流出道合并患者-人工瓣膜不匹配的成人患者,可考虑采用BeSPoKE技术以植入更大尺寸瓣膜并改善血流动力学。
局限性
- 样本量较小(25例)且为单中心回顾性研究,缺乏对照组,长期随访数据有限。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Aortic stenosis and prosthesis-patient mismatch complicate surgery for patients with small left ventricular outflow tracts. We present outcomes of a modified-Bentall single-patch Konno enlargement (BeSPoKE) technique for complex left ventricular outflow tract obstruction in adults. METHODS: The BeSPoKE technique facilitates a true outflow tract enlargement through an anterior septoventriculoplasty, using a single pericardial patch, followed by composite aortic valve-graft root replacement. Postoperative outflow tract geometry and valvular physiology were compared against preoperative measurements using echocardiography and computed tomographic angiography. Clinical outcomes at 2 years were assessed. RESULTS: From October 2017 to March 2022, 25 adults (median age, 60 years; 84% women) underwent a BeSPoKE repair. Mean preoperative aortic valve gradient was 44 ± 19 mm Hg. Twenty-one patients (84%) had previous aortic valve replacements with prosthesis-patient mismatch; median implant size preoperatively was 19 mm. Postoperatively, all patients received a prosthesis of at least 21 mm, with a median upsizing of 2 (15th-85th percentile, 2-3 sizes). Mean postoperative aortic valve gradient was 8.5 ± 4.1 mm Hg (P < .001). The mean 2-year gradient was 8.3 ± 1.3 mm Hg. All patients with bioprosthetic replacements qualified for future transcatheter valve replacements. Postoperative complications included atrial fibrillation in 9 (36%) and complete heart block requiring pacemaker placement in 8 (32%). There were no operative deaths, and no reoperations were reported. There were 2 late noncardiac-related deaths; 2-year survival was 92%. CONCLUSIONS: The BeSPoKE technique facilitates larger prosthesis placement, improves hemodynamics, and enables future transcatheter reinterventions. This approach is a safe treatment for complex left ventricular outflow tract obstruction and prosthesis-patient mismatch in adults.
引用
- Roselli EE, Kramer BP, Thompson MA, et al. Modified-Bentall Single-Patch Konno Enlargement Technique for Aortic Stenosis and Prosthesis-Patient Mismatch. Ann Thorac Surg. 2024. PMID: 39653107. doi:10.1016/j.athoracsur.2024.10.033
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。