机器人辅助主动脉瓣置换与冠状动脉旁路移植术
本文描述一例73岁女性,患有严重主动脉瓣反流、LAD 70%狭窄及EF 0.35,经右侧入路行全机器人主动脉瓣置换和LITA-LAD搭桥。术后恢复符合预期并出院。结论认为该术式可行,可能成为合并主动脉瓣与冠状动脉疾病患者的未来选择。
要点
- 右侧4cm单切口入路可完成全机器人主动脉瓣置换加LITA-LAD搭桥
- LITA获取时间43分钟,LAD吻合时间27分钟
- 高危 frail 患者术后恢复符合预期并出院
核心结论
- 机器人主动脉瓣置换联合冠状动脉旁路移植术可行,可能成为合并主动脉瓣与冠状动脉疾病患者的未来选择。
研究设计与样本
- 病例报告:73岁女性,严重主动脉瓣反流、LAD 70%狭窄、EF 0.35,BMI 17 kg/m2,STS预测死亡率10%。
主要发现
- 经右侧4cm单切口完成全机器人23mm生物瓣主动脉瓣置换和LITA-LAD搭桥。
- LITA获取时间43分钟,LAD吻合时间27分钟。
- frail 患者术后恢复符合预期并出院。
关键数值与推荐
- 患者因瓣叶钙化轻微,经导管选项被拒绝,转诊考虑高风险非胸骨切开手术。
临床怎么用
- 对于合并主动脉瓣和冠状动脉疾病的高危患者,可考虑机器人右侧入路同期手术。
局限性
- 单例病例报告,结论需更大样本验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Left chest robotic left internal thoracic artery (LITA) to left anterior descending (LAD) coronary revascularization has been established. We describe robotic aortic valve replacement and coronary artery bypass grafting through a right lateral approach. DESCRIPTION: A 73-year-old woman with severe aortic insufficiency, 70% LAD stenosis, and ejection fraction of 0.35 presented with recalcitrant symptoms. She sustained a stroke 1 year before surgery. She was frail, with a body mass index of 17 kg/m2. Her Society of Thoracic Surgeons predicted risk of mortality was 10%. Given minimal leaflet calcium, transcatheter options were declined, and she was referred for high-risk nonsternotomy surgical consideration. EVALUATION: After informed consent, a single-incision 4-cm right lateral working incision facilitated on-pump arrested fully robotic 23-mm bioprosthetic aortic valve replacement and LITA-LAD grafting. The LITA harvest time was 43 minutes, and LAD anastomosis was 27 minutes. This frail patient recovered expectantly and was discharged home. CONCLUSIONS: Robotic aortic valve replacement and coronary artery bypass grafting is feasible and may represent a viable future option for patients with concomitant aortic valve and coronary disease.
引用
- Badhwar V, Raikar GV, Darehzereshki A, et al. Robotic-Assisted Aortic Valve Replacement and Coronary Artery Bypass Grafting. Ann Thorac Surg. 2024. PMID: 39662654. doi:10.1016/j.athoracsur.2024.12.002