有创心输出量与左心室辅助装置流量参数的相关性比较
本研究回顾性分析2家三级医疗中心102例左心室辅助装置(LVAD)患者的右心导管检查数据,比较间接Fick法与热稀释法测得的心输出量与泵流量参数的相关性及一致性。结果显示泵流量参数与热稀释法相关性最强(R=0.789),与间接Fick法R=0.751;但两种方法均存在约45%-48%的不一致率。排除低心输出量值后相关性提高。
要点
- LVAD泵流量参数与热稀释法心输出量相关性最强(R=0.789)
- 间接Fick法与泵流量参数不一致率45%,热稀释法48%
- 排除低心输出量值后相关性提升至R>0.84
核心结论
- 当前LVAD流量参数提供的心输出量估计与间接Fick法相关性良好,与热稀释法相关性最强。
- 排除较低心输出量值后,泵流量参数与两种有创测量的相关性均增强。
研究设计与样本
- 回顾性研究,纳入2家三级医疗中心102例LVAD患者,共544次右心导管测量比较。
- 中位年龄58(51-64)岁,86%男性,LVAD植入后17 ± 12个月。
主要发现
- 间接Fick法与泵流量不一致率为45%(102/226),热稀释法与泵流量不一致率为48%(72/161)。
- 间接Fick法与LVAD流量参数相关系数R=0.751,热稀释法与LVAD流量参数R=0.789。
- 不一致相关的参数包括较高的主动脉瓣开放率、较低的间接Fick心输出量和较高的热稀释法心输出量。
- 排除间接Fick心输出量最低三分位后,热稀释法R=0.879,间接Fick法R=0.843(P < 0.001)。
临床怎么用
- LVAD流量参数可作为心输出量的估算工具,尤其在与热稀释法比较时相关性较强。
- 临床解读泵流量参数时需注意低心输出量状态下相关性下降,应结合有创测量综合评估。
局限性
- 回顾性设计,仅纳入2家中心,样本量有限。
- 不一致定义为测量间至少20%差异,可能存在方法学影响。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To evaluate the correlation between left ventricular assist device flow parameter and invasive cardiac output measurements. METHODS: We retrospectively evaluated right heart catheterization examinations performed in left ventricular assist device patients from 2 tertiary medical centres. We evaluated the correlation between cardiac output measurement methods (indirect Fick and thermodilution) and pump flow parameter using linear regression, and the agreement was graphically displayed using Bland-Altman plot technique. Clinical, echocardiographic, pump and haemodynamic parameters were compared between patients with and without discordance, defined as at least a 20% difference between measurements. RESULTS: The study population consisted of 102 patients [median age 58 (51-64), 86% males, 17 ± 12 months post left ventricular assist device implantation] with a total of 544 measurements compared. Discordance between measurements was present in 102 of 226 (45%) comparisons between indirect Fick and pump flow and in 72 of 161 (48%) between thermodilution and pump flow. A comparison of indirect Fick and left ventricular assist device exhibited a statistical correlation of R = 0.751, and that of thermodilution and left ventricular assist device of R = 0.789. Parameters associated with the presence of discordance between cardiac output measurements included a higher rate of aortic valve opening, lower indirect Fick and higher thermodilution cardiac output. After excluding the lowest tertile of indirect Fick cardiac output values, the correlation between measurements improved (thermodilution: R = 0.879 and indirect Fick: R = 0.843, P < 0.001). CONCLUSIONS: The current left ventricular assist device flow parameter provides an estimation of cardiac output that correlates well with indirect Fick and exhibits the strongest correlation with thermodilution. This correlation was stronger after excluding lower cardiac output values.
引用
- Segev A, Copeland V, Sokolski M, et al. Comparison between invasive cardiac output and left ventricular assist device flow parameter. Eur J Cardiothorac Surg. 2024. PMID: 39453988. doi:10.1093/ejcts/ezae383