全弓置换术后管腔形态与主动脉重塑:常规与冰冻象鼻支架对比
本研究纳入五家机构180例急性A型主动脉夹层行全弓置换患者(cET 88例,FET 92例),评估术后主动脉重塑。FET组完全重塑率显著高于cET组(63.4% vs 32.0%,P=0.0013)。基于椭圆傅里叶分析,四个层面平均PC2和PC3是完全重塑的独立预测因子。
要点
- FET组完全主动脉重塑率显著高于cET组(63.4% vs 32.0%,P=0.0013)。
- 残余真腔形态的PC2和PC3是全弓置换术后完全重塑的独立预测因子。
- 残余真腔形态分析或可辅助预测术后主动脉重塑。
核心结论
- 急性A型主动脉夹层全弓置换术中,FET的主动脉重塑率显著高于cET。
- 残余真腔的形态模式可作为预测术后主动脉重塑的重要参考。
研究设计与样本
- 采用椭圆傅里叶分析计算四个层面残余真腔形态的主成分值,并用逆概率治疗加权调整组间比较。
主要发现
- 完全主动脉重塑率FET组为63.4%,cET组为32.0%,差异显著(P=0.0013)。
- IPW调整后Fine-Gray回归显示,四个层面平均PC2(HR 0.22;P<0.001)和PC3(HR 0.24;P=0.009)是完全重塑的独立预测因子。
临床怎么用
- 在急性A型主动脉夹层全弓置换决策中,FET可能带来更高的主动脉重塑率。
- 可利用残余真腔形态的主成分分析辅助预测术后主动脉重塑。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: This study was performed to assess postoperative aortic remodelling (AR) after total arch replacement for acute type A aortic dissection (AAD) with a frozen elephant trunk (FET) or conventional elephant trunk (cET). Furthermore, the shape of the residual true lumen was analysed based on elliptical Fourier analysis and evaluated as a predictor of AR. METHODS: This study involved patients who underwent total arch replacement with a cET or FET for AAD from December 2006 to January 2023 at five institutions. AR was assessed at the levels of the 4th thoracic vertebra (Th4), Th7, Th10, and above the coeliac trunk. The shape of the residual true lumen at all four levels was analysed based on elliptical Fourier analysis to calculate shape patterns as principal component (PC) values. Inverse probability of treatment weighting was performed for adjustment between the groups. RESULTS: In total, 180 patients (88 with cET and 92 with FET) were enrolled. The complete AR rate, defined as false lumen remodelling throughout the entire descending thoracic aorta, was significantly higher in the FET than cET group (63.4% vs 32.0%, P = 0.0013). The inverse probability of treatment weighting-adjusted Fine-Gray regression model revealed that the mean PC2 (hazard ratio, 0.22; P < 0.001) and PC3 (hazard ratio, 0.24; P = 0.009) of the four levels were independent predictors of complete AR. CONCLUSIONS: In AAD repair, the AR rate was significantly higher with use of the FET than cET. The shape patterns of the residual true lumen can be an important reference for predicting postoperative AR.
引用
- Sato H, Iba Y, Mikami T, et al. Luminal shape and aortic remodelling after total arch replacement for type A aortic dissection: conventional and frozen elephant trunks. Eur J Cardiothorac Surg. 2024. PMID: 39460580. doi:10.1093/ejcts/ezae375
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。