文献速递心外重症与机械循环支持

心脏术后心源性休克的救援性IABP:是否需要转变策略?

The intra-aortic balloon pump as a rescue device: Do we need to shift our strategy for cardiogenic shock rescue after cardiac surgery?
PubMed 文献 · J Thorac Cardiovasc Surg · 2024-09-24

该研究纳入2012至2020年心脏手术后围术期置入IABP的成人患者,其中182例为救援性置入。救援性IABP与早期及1年死亡率升高相关,使用超过4天或心脏骤停作为指征提示预后更差,或非所有患者的最佳一线临时机械循环支持。

要点

  • 救援性IABP置入后院内救援失败率为17.6%,90天生存率80.8%,1年生存率76.9%。
  • IABP使用超过4天和心脏骤停作为指征是1年死亡率的危险因素。
  • 救援性IABP可能不是所有心源性休克患者的最佳一线临时机械循环支持。

核心结论

  • 心脏术后救援性IABP与早期和1年死亡率升高相关。
  • IABP使用超过4天或心脏骤停作为指征提示预后显著更差。
  • 救援性IABP可能不是所有患者的最佳一线临时机械循环支持,应早期考虑替代MCS策略。

研究设计与样本

  • 回顾性研究,纳入2012至2020年心脏手术后围术期置入救援性IABP的成人患者,排除移植和原发机械循环支持手术。
  • 共10,591例患者中397例(3.7%)接受围术期IABP,其中182例(45.8%)为救援性置入。

主要发现

  • 救援性IABP指征包括心脏切开术后休克66例(36.3%)、脱离体外循环失败58例(31.9%)、心肌缺血30例(16.5%)、心脏骤停25例(13.7%)、室性心律失常3例(1.6%)。
  • 院内救援失败率为17.6%(32/182),90天生存率80.8%,1年生存率76.9%。
  • 死亡最常见病因为持续性心源性休克(61.9%,26/42)。
  • IABP使用超过4天(校正风险比2.68,95%CI 1.31-5.50)和心脏骤停作为指征(校正风险比2.69,95%CI 1.11-6.54)是1年死亡率的危险因素。

临床怎么用

  • 心脏术后需救援性IABP的患者应警惕高死亡风险,尤其使用超过4天或因心脏骤停置入者。
  • 对心源性休克严重程度超出IABP支持能力的患者,应早期考虑替代临时机械循环支持策略。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: The intra-aortic balloon pump (IABP) is widely used to rescue patients from complications following cardiac surgery. Given improvements in rescue strategies over the past decade, the appropriateness of IABP must be reexamined. This study assessed the risk factors, outcomes, and predictors of survival of rescue IABP placement. METHODS: Patients receiving an isolated rescue IABP during or after cardiac surgery from 2012 to 2020 were studied. All adult patients undergoing cardiac surgery except transplantation and primary mechanical circulatory support (MCS) procedures were included. RESULTS: Of 10,591 patients, 397 (3.7%) received a perioperative IABP, including 182 (45.8%) with rescue IABP placement. The indications for rescue IABP were postcardiotomy shock (n = 66; 36.3%), failure to wean off cardiopulmonary bypass (n = 58; 31.9%), myocardial ischemia (n = 30; 16.5%), cardiac arrest (n = 25; 13.7%), and ventricular arrhythmia (n = 3; 1.6%). The in-hospital failure to rescue rate was 17.6% (n = 32 of 182) with a 90-day survival of 80.8% and 1-year survival of 76.9%. The most common etiology of mortality was ongoing cardiogenic shock (61.9%; n = 26 of 42). IABP use for >4 days and cardiac arrest as an indication for IABP were risk factors for 1-year mortality (adjusted hazard ratio, 2.68 [95% confidence interval (CI), 1.31-5.50] and 2.69 [95% CI, 1.11-6.54], respectively). CONCLUSIONS: Rescue IABP following cardiac surgery is associated with increased early and 1-year mortality. Prolonged IABP use beyond 4 days or cardiac arrest as an indication portended a significantly worse prognosis. Rescue IABP may not be the optimal first-line temporary MCS for all patients, as the level of support provided might not match the severity of cardiogenic shock. Alternative MCS strategies should be considered early.

来源:J Thorac Cardiovasc Surg,查看原文。版权归原作者所有。

引用

  1. Patel PB, Anyanwu A, Gross CR, et al. The intra-aortic balloon pump as a rescue device: Do we need to shift our strategy for cardiogenic shock rescue after cardiac surgery? J Thorac Cardiovasc Surg. 2024. PMID: 39326731. doi:10.1016/j.jtcvs.2024.09.029

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。