文献速递主动脉外科

基于同步辐射X射线相位层析成像的急性主动脉夹层新鲜壁密度研究

Density of fresh wall of acute aortic dissection with synchrotron-based x-ray phase tomography.
PubMed 文献 · Interdiscip Cardiovasc Thorac Surg · 2024-01-01

本研究应用动态同步辐射X射线相位对比层析成像技术,对5例急性A型主动脉夹层(ATAAD)患者的新鲜环形主动脉壁进行密度定量分析,并与5例尸检正常升主动脉对照。结果显示新鲜主动脉中膜(TM)总体密度为1.062 g/cm³,夹层与非夹层部分密度差异显著(1.05 vs 1.066 g/cm³,P=0.0122);拉伸变薄过程中TM密度保持不变;非夹层部分弹性纤维面积比低于正常(48.6% vs 60.5%,P<0.001)。

要点

  • ATAAD新鲜主动脉壁中膜密度在拉伸过程中保持不变
  • 夹层部分中膜密度显著低于非夹层部分(P=0.0122)
  • 非夹层部分弹性纤维面积比显著低于正常主动脉(P<0.001)

核心结论

  • 动态同步辐射X射线相位对比层析成像可追踪ATAAD新鲜主动脉的原位变形过程,并证实主动脉壁密度在拉伸过程中不变。

研究设计与样本

  • 实验研究,纳入5例ATAAD手术切除的新鲜环形主动脉标本(1男4女,年龄59.4±8.7岁),对照为5例尸检福尔马林固定正常升主动脉(2女,年龄59.7±5.5岁)。

主要发现

  • 新鲜主动脉中膜总体密度为1.062(SD 0.006)g/cm³,夹层部分密度为1.05(SD 0.004)g/cm³,非夹层部分为1.066(SD 0.004)g/cm³,两者差异显著(P=0.0122)。
  • 新鲜主动脉壁拉伸变薄时,中膜密度保持不变。
  • 非夹层部分中膜弹性纤维面积比为48.6(SD 7.1)%,正常主动脉为60.5(SD 5.7)%,非夹层部分显著低于正常(P<0.001)。

关键数值与推荐

  • 新鲜主动脉中膜总体密度:1.062(SD 0.006)g/cm³。
  • 夹层部分中膜密度:1.05(SD 0.004)g/cm³;非夹层部分:1.066(SD 0.004)g/cm³;P=0.0122。
  • 非夹层部分中膜弹性纤维面积比:48.6(SD 7.1)%;正常主动脉:60.5(SD 5.7)%;P<0.001。

临床怎么用

  • 动态同步辐射X射线相位对比层析成像可用于定量评估ATAAD新鲜主动脉壁的密度与变形特性。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: The mechanisms behind the onset of acute aortic dissection have not been fully elucidated. We developed dynamic synchrotron-based X-ray phase-contrast tomography to quantitatively study the dynamics of biological samples and applied it to the fresh aortic wall in acute type-A aortic dissection (ATAAD). METHODS: Fresh, ring-shaped aortas undergoing aortic repair in ATAAD were measured in a container filled with normal cold saline within 24 h of surgery. As a control, we obtained 5 formalin-fixed normal ascending aortas from autopsies (female: 2, 59.7 years) [standard deviation (SD): 5.5 years]. To evaluate the quantitative morphological change, we estimated the density at each step stretched by 2 mm per step. The fresh specimens were analysed pathologically using the area ratio of the elastic fibres. RESULTS: Samples were obtained from 5 patients [1 man and 4 women, 59.4 (SD: 8.7) years]. The overall density of the tunica media (TM) in the fresh aorta was 1.062 (SD: 0.006) g/cm3 and differed significantly between the dissected and non-dissected portions [1.05 (SD: 0.004) vs 1.066 (SD: 0.004) g/cm3, respectively; P = 0.0122]. When the fresh aortic wall was stretched and became thinner, the density of the TM remained unchanged. Compared with the pathological findings, the area ratios of the elastic fibres of the TM were lower in the non-dissected portion than normal [48.6 (SD: 7.1)% vs 60.5 (SD: 5.7 %, P < 0.001]. CONCLUSIONS: Dynamic synchrotron-based X-ray phase-contrast tomography can trace the deformation process that occurs in situ in fresh aorta in ATAAD. We confirmed that the densitometric property of the aortic wall in ATAAD was unchanged during the stretching process.

来源:Interdiscip Cardiovasc Thorac Surg,查看原文。版权归原作者所有。

引用

  1. Yokawa K, Hoshino M, Yagi N, et al. Density of fresh wall of acute aortic dissection with synchrotron-based x-ray phase tomography. Interdiscip Cardiovasc Thorac Surg. 2024. PMID: 39271147. doi:10.1093/icvts/ivae157

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。