文献速递心外重症与机械循环支持

双桶Impella置换术:不间断机械循环支持的可靠方法

The double barrel Impella exchange: A reliable method for uninterrupted mechanical circulatory support.
PubMed 文献 · J Heart Lung Transplant · 2024-07-17

该研究描述了双桶Impella置换技术,即新装置在旧装置仍在心室时并行置入,实现血流无缝过渡后再撤除旧装置。31例连续患者中无术中心脏骤停,96.8%(30/31)无新发主动脉瓣反流;OR 14.46,95%CI 1.74-119.93,p=0.01)。

要点

  • 双桶技术可在不中断血流的情况下完成Impella置换,避免经典置换中循环崩溃风险。
  • 31例患者中无术中心脏骤停,96.8%(30/31)无新发主动脉瓣反流。
  • 纯Impella组存活率83.3%(10/12)显著高于Impella联合ECMO组36.8%(7/19),OR 14.46(95%CI 1.74-119.93,p=0.01)。

核心结论

  • 双桶Impella置换技术在依赖装置的心源性休克患者中可靠,具有显著优势且风险极小。

研究设计与样本

  • 连续31例接受双桶Impella置换术患者的病例系列。

主要发现

  • 31例中无术中心脏骤停,96.8%(30/31)无新发主动脉瓣反流。
  • 1例在已知术前髂动脉损伤后发生血管并发症;1例发生非栓塞性卒中,另1例发生蛛网膜下腔出血。
  • 纯Impella组存活率为83.3%(10/12),Impella联合体外膜氧合(ECMO)组为36.8%(7/19),纯Impella组较联合组升高,OR 14.46(95%CI 1.74-119.93,p=0.01)。

临床怎么用

  • 在依赖装置的心源性休克患者中,双桶技术可实现不间断机械循环支持的Impella置换。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Classic Impella exchange interrupts flow when the old device is pulled into the aorta before advancing the new device across the aortic valve, threatening circulatory collapse and loss of left ventricular access. In "double barrel," uninterrupted Impella exchange, the new device is placed into the ventricle alongside the old, where flow is first transitioned completely. Of 31 consecutive patients undergoing this procedure, none experienced intraoperative cardiac arrest, and 96.8% (30/31) had no new aortic insufficiency. One vascular complication ensued following known preoperative iliac injury. One patient suffered nonembolic stroke; another had subarachnoid hemorrhage. Fifty-five percent (17/31) of patients survived, with 22.6% (7/31) recovering, 25.8% (8/31) undergoing transplant, and 6.5% (2/31) transitioning to durable left ventricular assist device. Impella-only survival (83.3%, 10/12) was significantly higher than Impella-extracorporeal membrane oxygenation survival (36.8%, 7/19; (operating room) OR 14.46, 95% ((confidence interval) CI 1.74-119.93, p = 0.01). We conclude the "double barrel" technique is reliable in device-dependent cardiogenic shock patients, offering significant advantages and minimal risk.

来源:J Heart Lung Transplant,查看原文。版权归原作者所有。

引用

  1. Clothier JS, Kobsa S, Praeger J, et al. The double barrel Impella exchange: A reliable method for uninterrupted mechanical circulatory support. J Heart Lung Transplant. 2024. PMID: 39029638. doi:10.1016/j.healun.2024.07.009

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。