文献速递主动脉外科

定制Relay®支架移植物用于主动脉弓0区和I区:两高容量中心经验

Evaluation of custom-made Relay® stent-grafts for aortic arch landing zones 0 and I: experience from two high-volume aortic centres.
PubMed 文献 · Eur J Cardiothorac Surg · 2024-01-01

回顾性分析两高容量主动脉中心2016年7月至2023年7月使用定制Relay®支架移植物治疗主动脉弓病变的35例患者,技术成功率100%,围术期无死亡,术后卒中2例(5.7%),随访平均35±26个月,再干预率低。

要点

  • 定制Relay®支架在主动脉弓0区和I区技术成功率达100%。
  • 围术期无死亡,术后卒中2例(5.7%),均恢复无致残缺陷。
  • 随访期间再干预率低,包括左颈总动脉桥接支架加固和左锁骨下动脉封堵各1例。

核心结论

  • 定制Relay®支架移植物平台在本研究中表现良好,技术成功率高,围术期卒中和死亡率低,随访期间再干预率低。

研究设计与样本

  • 回顾性分析两高容量主动脉中心2016年7月至2023年7月接受定制Relay®支架移植物(定制装置)治疗的所有患者,共35例(89%男性),平均年龄70±11岁。

主要发现

  • 治疗指征为穿透性主动脉溃疡14例(40%)、动脉瘤11例(31%)和主动脉夹层10例(29%)。
  • 9例(25.6%)使用近端扇贝形,9例(25.6%)使用1个大开窗,17例(48.8%)使用分支装置(单分支1例、双分支15例、三分支1例)。
  • 30例(86%)既往或同期行左锁骨下动脉血运重建;30天内无患者死亡;术后卒中2例(5.7%),均恢复无致残缺陷。
  • 平均随访35±26个月,随访期间6例(17.1%)死亡;1例需左颈总动脉桥接支架加固,1例需左锁骨下动脉封堵,3例接受远端延伸。

临床怎么用

  • 对于主动脉弓0区和I区病变,定制Relay®支架移植物可作为一种治疗选择,技术成功率高且围术期卒中与死亡率低。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To report experience with a Relay® stent-graft custom-made platform in treating different aortic arch pathology in 2 high-volume aortic centres. METHODS: A retrospective analysis of all patients treated between July 2016 and July 2023 with custom-made Relay® stent-graft (custom-made device). Underlying aortic arch pathology was an aneurysm, penetrating aortic ulcer, and dissection. Three custom-made device designs were used: proximal scallop, fenestrations, and inner branches. The endpoints were technical success, perioperative stroke, death, and reintervention rate. RESULTS: Thirty-five patients (89% males) with a mean age of 70 ± 11 years were treated.Indication for treatment was penetrating aortic ulcer in 14 patients (40%), aneurysm in 11 patients (31%) and aortic dissection in 10 patients (29%). The technical success rate was 100%. Twenty-eight patients (80%) had proximal sealing in zone 0, and 7 (20%) had proximal sealing in zone 1. Nine patients (25.6%) had proximal scallops, 9 (25.6%) had 1 big fenestration and 17 (48.8%) had a branched device; 1 with single branch, 15 with double branches and 1 with triple branches. Thirty patients (86%) had previous or simultaneous left subclavian artery revascularization. No patient died during 30 days. Two patients (5.7%) had stroke postoperatively; both recovered without disabling deficits. The mean follow-up was 35 ± 26 months. Six patients (17.1%) died during follow-up. One patient required reinforcement of the bridging stent in the left common carotid artery and one additional vascular plugging of the left subclavian artery. Three patients received distal extension. CONCLUSIONS: The Relay® stent-graft custom-made platform showed a good performance in our study with a high technical success rate, low perioperative stroke and mortality, and low reintervention rates during the follow-up.