文献速递冠心病外科

孤立性冠脉搭桥围术期输血风险预测模型:基于STS数据库

Risk of Transfusion in Isolated Coronary Artery Bypass Graft: Models Developed From The Society of Thoracic Surgeons Database.
PubMed 文献 · Ann Thorac Surg · 2024-07-05

基于STS成人心脏外科数据库2008-2016年1,266,545例孤立性CABG手术,657,821例(51.9%)接受围术期输血。研究开发了预测任何血制品、红细胞、新鲜冰冻血浆及血小板输注的完整模型,并构建了基于5个变量的快速风险评分。完整模型C统计量为0.785、0.815、0.707、0.699,快速评分为0.752、0.785、0.670、0.661,校准良好。

要点

  • 完整模型预测任何血制品、红细胞、新鲜冰冻血浆、血小板输注的C统计量分别为0.785、0.815、0.707、0.699。
  • 快速风险评分基于年龄、体表面积、性别、术前红细胞压积和主动脉内球囊反搏使用5个变量。
  • 观察风险与预期风险绝对差异在每个预期风险百分位均<10.8%,校准良好。

核心结论

  • 这些稳健且校准良好的CABG围术期输血风险评估工具可告知外科医生患者输血风险及预期需要的红细胞、新鲜冰冻血浆和血小板单位数,有助于优化结局并提高血制品使用效率。

研究设计与样本

  • 基于STS成人心脏外科数据库2008-2016年1,266,545例连续孤立性CABG手术的回顾性分析,其中657,821例(51.9%)接受围术期输血。

主要发现

  • 完整模型预测任何血制品、红细胞、新鲜冰冻血浆、血小板的C统计量分别为0.785、0.815、0.707、0.699。
  • 快速风险评分预测任何血制品、红细胞、新鲜冰冻血浆、血小板的C统计量分别为0.752、0.785、0.670、0.661。
  • 观察风险与预期风险绝对差异在每个预期风险百分位均<10.8%。
  • 风险评分预测的输血概率与总输血单位数呈强非线性关联(P < .0001)。

关键数值与推荐

  • 快速风险评分基于5个变量:年龄、体表面积、性别、术前红细胞压积和主动脉内球囊反搏使用。

临床怎么用

  • 这些风险评估工具可告知外科医生患者围术期输血风险及预期需要的红细胞、新鲜冰冻血浆和血小板单位数,以辅助优化结局和提高血制品使用效率。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Perioperative blood transfusion is associated with adverse outcomes and higher costs after coronary artery bypass graft (CABG) surgery. We developed risk assessments for patients' probability of perioperative transfusion and the expected transfusion volume to improve clinical management and resource use. METHODS: Among 1,266,545 consecutive (2008-2016) isolated CABG operations in The Society of Thoracic Surgeons Adult Cardiac Surgery Database, 657,821 (51.9%) received perioperative transfusions of red blood cells (RBC), fresh frozen plasma (FFP), cryoprecipitate, and/or platelets. We developed "full" models to predict perioperative transfusion of any blood product, and of RBC, FFP, or platelets. Using least absolute shrinkage and selection operator model selection, we built a rapid risk score based on 5 variables (age, body surface area, sex, preoperative hematocrit, and use of intra-aortic balloon pump). RESULTS: C statistics for the full model were 0.785, 0.815, 0.707, and 0.699 for any blood product, RBC, FFP, and platelets, respectively. C statistics for rapid risk assessments were 0.752, 0.785, 0.670, and 0.661 for any blood product, RBC, FFP, and platelets, respectively. The observed vs expected risk plots showed strong calibration for full models and risk assessment tools; absolute differences between observed and expected risks of transfusion were <10.8% in each percentile of expected risk. Risk assessment-predicted probabilities of transfusion were strongly and nonlinearly associated (P < .0001) with total units transfused. CONCLUSIONS: These robust and well-calibrated risk assessment tools for perioperative transfusion in CABG can inform surgeons regarding patients' risks and the number of RBC, FFP, and platelets units they can expect to need. This can aid in optimizing outcomes and increasing efficient use of blood products.

来源:Ann Thorac Surg,查看原文。版权归原作者所有。

引用

  1. Edgerton JR, Filardo G, Pollock BD, et al. Risk of Transfusion in Isolated Coronary Artery Bypass Graft: Models Developed From The Society of Thoracic Surgeons Database. Ann Thorac Surg. 2024. PMID: 38972369. doi:10.1016/j.athoracsur.2024.06.022

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。