主动脉根部替换术中不良技术事件:发生率、危险因素与预后
该单中心回顾性研究纳入2012至2022年830例连续主动脉根部替换术(ARR),术中不良技术事件发生率为10.8%(90例)。既往胸骨切开术(OR 2.38)和复杂主动脉瓣疾病(OR 3.09)与技术事件相关;
要点
- ARR术中不良技术事件发生率为10.8%,出血、非缺血性室功能不全、残余瓣膜病为常见原因。
- 既往胸骨切开术(OR 2.38)和复杂主动脉瓣疾病(OR 3.09)与技术事件风险升高相关。
- 发生技术事件者手术死亡率(6.7% vs 2.3%)及所有主要术后并发症发生率更高。
核心结论
- 不良技术事件发生于10.8%的ARR中,与再次胸骨切开术相关;技术事件与术后并发症增加相关。
研究设计与样本
- 单中心回顾性研究,纳入2012年至2022年830例连续主动脉根部替换术(ARR)患者;技术事件定义为导致计划外心脏手术、需机械循环支持或额外主动脉阻断的术中事件;采用Logistic回归分析手术死亡和技术事件的相关因素。
主要发现
- 技术事件发生于90例(10.8%),归因于出血(n=26)、非缺血性心室功能障碍(n=23)、残余瓣膜病(n=20)、心肌缺血(n=19)和医源性夹层(n=2)。
临床怎么用
- 对既往胸骨切开术或复杂主动脉瓣疾病的患者行ARR时,应警惕术中不良技术事件的发生。
- 发生技术事件后需关注术后并发症的防治。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Although adverse technical events during aortic root replacement (ARR) are not uncommon and are extremely challenging, there is scant literature to help surgeons prepare for such situations. We describe our experience of outstanding technical events during ARR. METHODS: This is a retrospective study of 830 consecutive ARRs at a single center from 2012 to 2022. Technical events were defined as intraoperative events that led to an unplanned cardiac procedure, need for mechanical circulatory support, or additional aortic cross-clamping. Logistic regression identified factors associated with operative mortality and technical events. RESULTS: Technical events occurred in 90 patients (10.8%) and were attributed to bleeding (n = 26), nonischemic ventricular dysfunction (n = 23), residual valve disease (n = 20), myocardial ischemia (n = 19), and iatrogenic dissection (n = 2). Prior sternotomy (odds ratio [OR], 2.38; 95% CI, 1.36-4.19; P = .002) and complex aortic valve disease (OR, 3.09; 95% CI, 1.09-8.75; P = .03) were associated with technical events. Patients with technical events had higher rates of operative mortality (6.7% vs 2.3%, P = .03) and all major postoperative complications. Surgical indications of dissection (OR, 13.57; 95% CI, 4.95-37.23; P < .001) and complex aortic valve disease (OR, 14.09; 95% CI, 3.67-54.02; P < .001) but not adverse technical events (OR, 2.42; 95% CI, 0.81-7.26; P = .11) were associated with operative mortality. CONCLUSIONS: Adverse technical events occurred in 10.8% of ARRs and were associated with reoperative sternotomies. Technical events are associated with increased postoperative complications.
引用
- Chung M, Rajesh K, Hohri Y, et al. Adverse Technical Events During Aortic Root Replacement. Ann Thorac Surg. 2024. PMID: 38936593. doi:10.1016/j.athoracsur.2024.06.014
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。