文献速递主动脉外科

升主动脉瘤壁应力随时间变化预测全因死亡

Temporal evolution of ascending aortic aneurysm wall stress predicts all-cause mortality.
PubMed 文献 · Interdiscip Cardiovasc Thorac Surg · 2024-01-01

混合效应模型显示峰值圆周应力年变化1.19 kPa/年,Cox模型显示其年增长与全因死亡风险相关,而直径和长度变化不相关。

要点

  • 峰值圆周应力年变化与全因死亡风险独立相关,直径和长度变化不相关。
  • 峰值圆周应力每增长10 kPa/年,死亡风险比HR 1.27(95%CI 1.02-1.60;P=0.037)。
  • 峰值圆周应力增长≥32 kPa/年者死亡风险比为8.47(95%CI 2.42-30;P<0.001)。

核心结论

  • 在非手术升主动脉瘤患者中,峰值圆周应力的大幅时间变化与全因死亡相关,而主动脉直径或长度变化不相关。
  • 生物力学应力及其随时间变化可能作为小动脉瘤择期手术的额外风险因素。

研究设计与样本

  • 采用混合效应模型评估时间趋势,Cox比例风险模型评估应力、直径和长度变化对后续3年全因死亡的预测价值。

主要发现

  • 主动脉直径年变化0.12 mm/年(95%CI 0.04-0.20),主动脉长度年变化0.41 mm/年(95%CI 0.12-0.71)。
  • 峰值圆周应力年变化1.19 kPa/年(95%CI -5.94至8.33),峰值纵向应力年变化0.48 kPa/年(95%CI -3.89至4.84)。
  • 峰值圆周应力每增长10 kPa/年,死亡风险比HR 1.27(95%CI 1.02-1.60;P=0.037)。
  • 峰值圆周应力增长≥32 kPa/年,死亡风险比HR 8.47(95%CI 2.42-30;P<0.001)。

临床怎么用

  • 对于升主动脉瘤小于5.5 cm的非手术患者,除直径外可考虑评估峰值圆周应力及其随时间变化。
  • 生物力学应力变化可能作为小动脉瘤择期手术决策的额外风险参考因素。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Diameter-based risk stratification for elective repair of ascending aortic aneurysm fails to prevent type A dissection in many patients. Aneurysm wall stresses may contribute to risk prediction; however, rates of wall stress change over time are poorly understood. Our objective was to examine aneurysm wall stress changes over 3-5 years and subsequent all-cause mortality. METHODS: Male veterans with <5.5 cm ascending aortic aneurysms and computed tomography at baseline and 3- to 5-year follow-up underwent three-dimensional aneurysm model construction. Peak circumferential and longitudinal wall stresses at systole were calculated using finite element analysis. Temporal trends were assessed by mixed-effects modelling. Changes in aortic wall stresses, diameter and length over time were evaluated as predictors of subsequent 3-year all-cause mortality by Cox proportional hazards modelling. RESULTS: Sixty-two male veterans were included in the study. Yearly changes in geometric and biomechanical measures were 0.12 mm/year (95% confidence interval, 0.04-0.20) for aortic diameter, 0.41 mm/year (0.12-0.71) for aortic length, 1.19 kPa/year -5.94 to 8.33) for peak circumferential stress, and 0.48 kPa/year (-3.89 to 4.84) for peak longitudinal stress. Yearly change in peak circumferential stress was significantly associated with hazard of death-hazard ratio for peak circumferential stress growth per 10 kPa/year, 1.27 (95% CI, 1.02-1.60; P = 0.037); hazard ratio for peak circumferential stress growth ≥ 32 kPa/year, 8.47 (95% CI, 2.42-30; P < 0.001). CONCLUSIONS: In this population of nonsurgical aneurysm patients, large temporal changes in peak circumferential stress, but not aortic diameter or length, was associated with all-cause mortality. Biomechanical stress and stress changes over time may be beneficial as additional risk factors for elective surgery in small aneurysms.

来源:Interdiscip Cardiovasc Thorac Surg,查看原文。版权归原作者所有。

引用

  1. Zamirpour S, Gulati A, Xuan Y, et al. Temporal evolution of ascending aortic aneurysm wall stress predicts all-cause mortality. Interdiscip Cardiovasc Thorac Surg. 2024. PMID: 38913870. doi:10.1093/icvts/ivae116

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。