新植入三尖瓣生物瓣的瓣叶运动受限:发生率、预测因素及对生存的影响

Restricted cusp motion in newly implanted tricuspid bioprostheses: Incidence, predictors, and impact on survival.
PubMed 文献 · J Thorac Cardiovasc Surg · 2024-05-31

本研究回顾性分析2012至2022年在本机构接受三尖瓣生物瓣置换的476例成人患者,通过术中经食管超声发现31.5%存在瓣叶运动受限(完全不动13.2%、活动受限18.3%);Hancock II型号、较大瓣口面积、较小体表面积和较低射血分数为独立预测因素,瓣叶运动受限与远期死亡风险升高独立相关(HR 1.35,P=0.049)。

要点

  • 三尖瓣生物瓣置换后即刻经食管超声发现瓣叶运动受限发生率达31.5%。
  • Hancock II型号、较大瓣口面积、较小体表面积及较低射血分数与瓣叶运动受限独立相关。
  • 瓣叶运动受限与远期死亡风险升高独立相关(HR 1.35,P=0.049)。

核心结论

  • 三尖瓣位置生物瓣植入后即刻经食管超声发现瓣叶运动受限发生率高,且与远期死亡率升高相关。
  • 为降低瓣叶运动受限概率,选择合适的人工瓣膜型号和尺寸很重要,尤其对于小体型患者。

研究设计与样本

  • 回顾性研究,纳入2012年至2022年在本机构接受三尖瓣生物瓣置换的成人患者。
  • 通过详细审阅术中经食管超声心动图重新分析生物瓣瓣叶运动。
  • 植入两种猪瓣膜型号:Medtronic Hancock II生物瓣和St Jude Medical Epic生物瓣。
  • 共476例患者符合纳入标准。

主要发现

  • 476例患者中,150例(31.5%)在旁路移植后即刻经食管超声发现瓣叶运动受限。
  • 其中63例(13.2%)为瓣叶完全不动,87例(18.3%)为瓣叶活动受限。
  • 多变量逻辑回归分析显示,Hancock II型号(OR 6.15,P<0.001)、较大瓣口面积(每IQR增加:OR 1.58,P=0.017)、较小体表面积(每IQR增加:OR 0.68,P=0.040)和较低射血分数(每IQR增加:OR 0.60,P=0.033)与瓣叶运动受限独立相关。
  • 校正15个协变量的Cox回归显示,三尖瓣置换时瓣叶运动受限与死亡风险升高独立相关(HR 1.35,P=0.049)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To investigate the occurrence of restricted cusp motion (RCM) at the time of bioprosthetic tricuspid valve replacement (TVR) and analyze associated risk factors and outcomes. METHODS: This study involved adult patients who underwent TVR with a bioprosthesis at our institution between 2012 and 2022. Bioprosthetic cusp motion was analyzed de novo through a detailed review of intraoperative transesophageal echocardiograms (TEE). Two models of porcine valves were implanted: the Medtronic Hancock II bioprosthesis and the St Jude Medical Epic bioprosthesis. RESULTS: Among the 476 patients who met the inclusion criteria, RCM was identified on immediate post-bypass TEE in 150 (31.5%); there was complete immobility of the cusp in 63 patients (13.2%) and limited movement of a cusp in 87 patients (18.3%). In a multivariable logistic regression analysis, the Hancock II model (odds ratio [OR], 6.15; P < .001), a larger orifice area (per IQR increase: OR, 1.58; P = .017), a smaller body surface area (per IQR increase: OR, .68; P = .040), and a lower ejection fraction (per IQR increase: OR, .60; P = .033) were independently associated with having RCM. Cox regression adjusting for 15 covariates revealed that RCM at the time of TVR was independently associated with an increased risk of mortality (hazard ratio, 1.35; P = .049). CONCLUSIONS: This study revealed a high incidence of RCM in bioprosthetic valves in the tricuspid position detected shortly postimplantation, which was associated with increased late mortality. To reduce the probability of RCM, it is important to select the appropriate prosthesis model and size, particularly in small patients.