研究评估计算预测模型在经导管主动脉瓣置换术(TAVR)规划中对冠状动脉闭塞(CO)的临床影响。2020年1月至2022年12月,116例(7.6%)按传统标准判定为CO风险增高的患者接受了前瞻性计算建模(DASI Simulations),并回顾性分析手术修改与临床结果。计算建模预测39例(31.9%)CO风险增高,其中29例继续行TAVR并采取手术修改,术后未发生冠状动脉受损事件。作者认为术前模拟是手术规划的有效增强。
要点
- 116例传统标准评估CO风险增高的TAVR患者接受了计算预测建模。
- 建模预测39例(31.9%)CO风险增高,其中29例继续行TAVR并采取手术修改。
- 术后预测高风险(经手术修改)与低风险(标准TAVR)患者均无冠状动脉受损事件。
核心结论
- 作者认为,通过计算预测建模对患者特异性几何结构进行TAVR术前模拟,是手术规划的有效增强。
研究设计与样本
- 回顾性分析2020年1月至2022年12月期间接受TAVR评估、按传统标准判定为CO风险增高的116例(7.6%)患者,患者接受前瞻性计算建模(DASI Simulations),并回顾性审查手术修改与临床结果。
主要发现
- 116例CO风险患者中,53例为原生主动脉瓣狭窄(45.7%),47例有既往外科主动脉瓣置换史(40.5%),16例有既往TAVR史(13.8%)。
- 计算建模预测39/116例(31.9%)CO风险增高,其中29例继续行TAVR。
- 为降低CO风险采取的手术修改包括:TAVR中生物瓣或原生主动脉瓣叶意向性裂开以预防医源性冠状动脉梗阻(n=10)、烟囱冠状动脉支架(n=8)、无支架冠状动脉通路(n=3)。
- 预测高风险(经手术修改)与预测低风险(标准TAVR)患者TAVR术后均无冠状动脉受损事件。
临床怎么用
- 作者认为,术前计算预测建模模拟是TAVR手术规划的有效增强。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Coronary artery occlusion (CO) during transcatheter aortic valve replacement (TAVR) is a devastating complication. The objective of this study was to assess the clinical impact of a computational predictive modeling algorithm for CO during TAVR planning. METHODS: From January 2020 to December 2022, 116 patients (7.6%) who underwent TAVR evaluation were deemed to be at increased risk of CO on the basis of traditional criteria. Patients underwent prospective computational modeling (DASI Simulations) to assess their risk of CO during TAVR; procedural modifications and clinical results were reviewed retrospectively. RESULTS: Of the 116 patients at risk for CO by traditional methodology, 53 had native aortic valve stenosis (45.7%), 47 had undergone previous surgical AVR (40.5%), and 16 had undergone previous TAVR (13.8%). Transcatheter valve choice, size, or implantation depth was modeled for all patients. Computational modeling predicted an increased risk of CO in 39 of 116 (31.9%) patients. Within this subcohort, 29 patients proceeded with TAVR. Procedural modifications to augment the risk of CO included bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction during TAVR (n = 10), chimney coronary stents (n = 8), and coronary access without stents (n = 3). There were no episodes of coronary artery compromise among patients after TAVR, either for those predicted to be at high risk of CO (with procedural modifications) or those predicted to be at low risk (standard TAVR). CONCLUSIONS: The use of preoperative simulations for TAVR in patient-specific geometry through computational predictive modeling of CO is an effective enhancement to procedure planning.