文献速递瓣膜外科

二尖瓣手术同期三尖瓣修复术后起搏器植入的决定因素

Simultaneous tricuspid valve repair at the time of mitral valve surgery: Determinants of postoperative pacemaker implantation.
PubMed 文献 · J Thorac Cardiovasc Surg · 2024-05-27

本研究回顾2001至2022年因退行性二尖瓣病变接受二尖瓣手术同期三尖瓣修复的404例患者,术后起搏器植入率为8.7%,其中6.4%因高度房室传导阻滞植入。多变量分析仅年龄与起搏器植入相关,因高度房室传导阻滞植入起搏器者总体生存率降低(P = .01)。

要点

  • 二尖瓣手术同期三尖瓣修复术后起搏器植入率为8.7%,高度房室传导阻滞为6.4%。
  • 多变量分析仅年龄与术后起搏器植入相关。
  • 因高度房室传导阻滞植入起搏器者总体生存率降低(P = .01)。

核心结论

  • 二尖瓣手术同期三尖瓣修复术后需要永久起搏并不少见,但可改变的风险因素很少。
  • 作者认为,仔细选择三尖瓣反流未达重度的患者及手术技术可能降低起搏器相关风险和并发症。

研究设计与样本

  • 回顾性研究,纳入2001至2022年因退行性二尖瓣病变接受二尖瓣手术同期三尖瓣修复的患者404例。
  • 主要终点为术后永久起搏器植入发生率,次要终点包括高度房室传导阻滞发生率和总体生存率。

主要发现

  • 所有患者均行三尖瓣修复,其中332例(82%)行二尖瓣修复,72例(18%)行二尖瓣置换。
  • 三尖瓣修复技术包括柔性带258例(63.8%)、DeVega成形78例(19.3%)、完整柔性环49例(12.1%)和不完整硬质环19例(4.7%)。
  • 30天死亡率为0.5%(n = 2)。
  • 35例(8.7%)患者术后植入永久起搏器,其中26例(6.4%)因高度房室传导阻滞植入。
  • 多变量分析仅年龄与起搏器植入相关;因高度房室传导阻滞植入起搏器的患者总体生存率降低(P = .01)。

临床怎么用

  • 作者认为,仔细选择三尖瓣反流未达重度的患者及手术技术可能降低起搏器相关风险和并发症。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Guidelines recommend tricuspid valve (TV) repair for patients with severe tricuspid valve regurgitation (TR) undergoing surgery for degenerative mitral valve (MV) disease, but management of moderate or greater TR is controversial. This study examines the incidence and causes of bradyarrhythmia leading to permanent pacemaker (PPM) implantation. METHODS: We reviewed patients undergoing simultaneous TV repair and MV surgery for degenerative MV disease from 2001 to 2022 (N = 404). Primary end point was the incidence of postoperative PPM implantation. Secondary end points included the incidence of high-degree atrioventricular (AV) block and overall survival. RESULTS: All patients underwent TV repair at the time of MV surgery; 332 (82%) underwent MV repair and 72 (18%) MV replacement. TV repair techniques included flexible band (n = 258, 63.8%), DeVega annuloplasty (n = 78, 19.3%), complete flexible ring (n = 49, 12.1%), and incomplete rigid ring (n = 19, 4.7%). The 30-day mortality was 0.5% (n = 2). A total of 35 (8.7%) patients had a PPM implanted postoperatively, 26 (6.4%) for high-degree AV block. On multivariable analysis, only older age was associated with PPM implantation. Patients who received a PPM as the result of high-degree AV block had reduced overall survival (P = .01). CONCLUSIONS: Need for permanent pacing after TV repair at the time of MV surgery is not uncommon, but there are few modifiable factors that might reduce this risk. Careful selection of patients with less-than-severe TR and surgical techniques may reduce PPM-related risks and complications.

来源:J Thorac Cardiovasc Surg,查看原文。版权归原作者所有。

引用

  1. Juarez-Casso FM, Schaff HV, Todd A, et al. Simultaneous tricuspid valve repair at the time of mitral valve surgery: Determinants of postoperative pacemaker implantation. J Thorac Cardiovasc Surg. 2024. PMID: 38810791. doi:10.1016/j.jtcvs.2024.05.018

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。