文献速递瓣膜外科

外科主动脉瓣置换术后患者-人工瓣膜不匹配:PARTNER试验分析

Patient-Prosthesis Mismatch After Surgical Aortic Valve Replacement: Analysis of the PARTNER Trials.
PubMed 文献 · Ann Thorac Surg · 2024-02-03

基于PARTNER 1、2、3试验的前瞻性随机外科主动脉瓣置换患者,比较预测法与实测法定义的患者-人工瓣膜不匹配(PPM)对2年全因死亡与心衰再住院复合终点的影响。预测法重度PPM仅2.1%,实测法为21.6%;两种方法下重度PPM均与更差结局相关。

要点

  • 预测法PPM:无59.1%、中度38.8%、重度2.1%;实测法:无42.4%、中度36.0%、重度21.6%。
  • 预测法无PPM者主要终点23.6%,低于中度28.2%(P=.03)和重度38.8%(P=.02)。
  • 实测法无PPM与中度PPM主要终点无差异(17.7% vs 21.1%,P=.16),但均优于重度PPM(27.4%)。

核心结论

  • 预测法分析的外科主动脉瓣置换患者重度PPM仅2.1%。
  • 实测法相对于预测法高估了重度PPM发生率,但也与更差结局相关。
  • 重度PPM患者全因死亡率更高,因此尽量减少PPM的外科技术仍然至关重要。

研究设计与样本

  • 前瞻性随机PARTNER 1、2、3试验中外科主动脉瓣置换患者的分析。
  • PPM定义为中度(指数化有效瓣口面积≤0.85 cm2/m2)或重度(≤0.65 cm2/m2)。
  • 主要终点为2年全因死亡与心衰再住院的复合终点。

主要发现

  • 预测法PPM:无PPM 59.1%,中度38.8%,重度2.1%。
  • 实测法PPM:无PPM 42.4%,中度36.0%,重度21.6%。
  • 预测法无PPM者主要终点23.6%,低于中度PPM 28.2%(P=.03)和重度PPM 38.8%(P=.02)。
  • 实测法无PPM与中度PPM主要终点无差异(17.7% vs 21.1%,P=.16)。
  • 实测法无PPM和中度PPM均优于重度PPM(27.4%,P<.001和P=.02)。

关键数值与推荐

  • PPM中度:指数化有效瓣口面积≤0.85 cm2/m2;重度:≤0.65 cm2/m2。
  • 预测法无PPM 59.1%、中度38.8%、重度2.1%。
  • 实测法无PPM 42.4%、中度36.0%、重度21.6%。

临床怎么用

  • 原文未据此给出推荐。
  • 作者认为,重度PPM患者全因死亡率更高,因此尽量减少PPM的外科技术仍然至关重要。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Our objective was to compare the impact of patient-prosthesis mismatch (PPM) for 2 years after surgical aortic valve replacement within the prospective, randomized Placement of Aortic Transcatheter Valves (PARTNER) trials. METHODS: Surgical aortic valve replacement patients from the PARTNER 1, 2, and 3 trials were included. PPM was classified as moderate (indexed effective orifice area ≤0.85 cm2/m2) or severe (indexed effective orifice area ≤0.65 cm2/m2). The primary endpoint was the composite of all-cause death and heart failure rehospitalization at 2 years. RESULTS: By the predicted PPM method (PPMP), 59.1% had no PPM, 38.8% moderate PPM, and 2.1% severe PPM; whereas by the measured PPM method (PPMM), 42.4% had no PPM, 36.0% moderate, and 21.6% severe. Patients with no PPMP (23.6%) had a lower rate of the primary endpoint compared with patients with moderate (28.2%, P = .03) or severe PPMP (38.8%, P = .02). Using the PPMM method, there was no difference between the no (17.7%) and moderate PPMM groups (21.1%) in the primary outcome (P = .16). However, those with no PPMM or moderate PPMM were improved compared with severe PPMM (27.4%, P < .001 and P = .02, respectively). CONCLUSIONS: Severe PPM analyzed by PPMP was only 2.1% for surgical aortic valve replacement patients. The PPMM method overestimated the incidence of severe PPM relative to PPMP, but was also associated with worse outcome. There was higher all-cause mortality in patients with severe PPM, thus surgical techniques to minimize PPM remain critical.

来源:Ann Thorac Surg,查看原文。版权归原作者所有。

引用

  1. Thourani VH, Abbas AE, Ternacle J, et al. Patient-Prosthesis Mismatch After Surgical Aortic Valve Replacement: Analysis of the PARTNER Trials. Ann Thorac Surg. 2024. PMID: 38316377. doi:10.1016/j.athoracsur.2024.01.023

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。