文献速递瓣膜外科

计算机断层扫描预测内镜二尖瓣手术暴露不佳

Prediction of poor exposure in endoscopic mitral valve surgery using computed tomography.
PubMed 文献 · Eur J Cardiothorac Surg · 2024-01-01

本研究纳入263例内镜二尖瓣手术患者,术前用体重指数和CT测量建立暴露不佳预测模型。作者认为暴露不佳约占四分之一,或可术前预测以帮助确定手术入路。

要点

  • 体重指数、胸宽、左心室心尖角、心脏宽度和Δ膈肌为独立预测因子。
  • 预测模型曲线下面积0.822(P<0.001),Δ膈肌对3级暴露曲线下面积0.826。

核心结论

  • 内镜二尖瓣手术中暴露不佳约占四分之一,或可术前用体重指数和CT测量预测以帮助确定手术入路。

研究设计与样本

  • 纳入有手术视频和术前CT的内镜二尖瓣手术患者263例,将瓣膜暴露分为0级(优)131例(49.8%)、1级(良)72例(27.4%)、2级(差)46例(17.5%)、3级(极差)14例(5.3%)。
  • 测量胸廓前后径、左右径、右半胸高度、左心室轴线与水平面夹角(左心室心尖角)、心脏宽度、中线膈肌水平及中线膈肌水平与右膈最高点垂直距离(Δ膈肌)。

主要发现

  • 逐步logistic回归分析显示,体重指数、胸宽、左心室心尖角、心脏宽度和Δ膈肌是2级和3级暴露的独立预测因子,受试者工作特征曲线下面积为0.822(P<0.001)。
  • 预测3级暴露的单因素logistic回归显示,Δ膈肌的曲线下面积最大(0.826,P<0.001)。

临床怎么用

  • 作者认为,术前用体重指数和CT测量或可预测内镜二尖瓣手术暴露不佳,以帮助确定手术入路。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: In endoscopic mitral valve surgery, optimal exposure is crucial. This study aims to develop a predictive model for poor mitral valve exposure in endoscopic surgery, utilizing preoperative body profiles and computed tomography images. METHODS: We enrolled patients undergoing endoscopic mitral valve surgery with available operative video and preoperative computed tomography. The degree of valve exposure was graded into 0 (excellent), 1 (fair), 2 (poor) and 3 (very poor). Intrathoracic dimensions-anteroposterior width (chest anteroposterior) and left-to-right width (chest width) of the thorax, height of right hemi-thorax (chest height), angle between the left ventricular axis and the horizontal plane (left ventricle apex angle), heart width, level of diaphragm in midline, and vertical distance between the midline diaphragm level and the highest top of the right diaphragm (Δdiaphragm) were measured. RESULTS: Among 263 patients, mitral valve exposure was graded as 0 in 131 (49.8%), 1 in 72 (27.4%), 2 in 46 (17.5%) and 3 in 14 (5.3%). Body mass index, chest width, left ventricle apex angle, heart width and Δdiaphragm were identified as independent predictors of grades 2 and 3 exposure by stepwise logistic regression analysis, with an area under the receiver operating characteristic curve of 0.822 (P < 0.001). Univariate logistic regression for grade 3 exposure prediction revealed that Δdiaphragm had the largest area under the curve (0.826, P < 0.001). CONCLUSIONS: Poor mitral valve exposure occurred in approximately one-fourth of the endoscopic surgery series and might be predicted preoperatively using body mass index and computed tomography measurements to help determine the surgical approach.

来源:Eur J Cardiothorac Surg,查看原文。版权归原作者所有。

引用

  1. Jung Y, van Kuijk SMJ, Gietema H, et al. Prediction of poor exposure in endoscopic mitral valve surgery using computed tomography. Eur J Cardiothorac Surg. 2024. PMID: 38420651. doi:10.1093/ejcts/ezae070

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。