本研究采用磁共振相位对比成像评估单心室合并单侧膈肌麻痹(DP)患儿Glenn/Fontan循环中左右肺动脉每搏输出量指数(SVI)。共分析18例单侧DP患者(Glenn期8例,Fontan期10例;右侧DP 10例,左侧DP 8例;7例行膈肌折叠术),对照组为36例无DP的Glenn(16例)/Fontan(20例)患者。结果显示左侧和右侧DP患者同侧肺动脉SVI均显著低于对照组,对侧SVI略有增加但无统计学意义。结论认为单侧DP对麻痹侧肺动脉SVI有负面影响。
要点
- 单侧膈肌麻痹患儿Glenn/Fontan循环中,同侧肺动脉每搏输出量指数显著降低。
- 左侧膈肌麻痹同侧SVI为2.81 ml/m2,对照组为11.97 ml/m2(P < 0.0002)。
- 右侧膈肌麻痹同侧SVI为8.2 ml/m2,对照组为12.64 ml/m2(P = 0.0284)。
核心结论
- 单心室合并单侧膈肌麻痹患者Glenn/Fontan循环中,麻痹侧肺动脉每搏输出量指数受到负面影响。
研究设计与样本
- 采用磁共振相位对比成像评估左右肺动脉每搏输出量指数。
- 分析18例单心室合并单侧膈肌麻痹患者,其中Glenn期8例、Fontan期10例;右侧膈肌麻痹10例,左侧8例;7例行膈肌折叠术。
- 对照组为36例无膈肌麻痹的Glenn(16例)/Fontan(20例)循环患者。
主要发现
- 左侧膈肌麻痹患者同侧SVI为2.81(1.45-4.50)ml/m2,对照组为11.97(7.36-16.37)ml/m2,P < 0.0002。
- 右侧膈肌麻痹患者同侧SVI为8.2(4.49-12.64)ml/m2,对照组为12.64(9.66-16.61)ml/m2,P = 0.0284。
- 单侧膈肌麻痹患者对侧SVI略有增加,但无统计学显著差异。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Spontaneous breathing has an important effect on pulmonary arterial blood flow in patients with Glenn/Fontan circulation. Unilateral diaphragmatic paralysis (DP) is a frequent complication after heart surgery in congenital heart disease. The aim of this study was to investigate the influence of unilateral DP on blood flow distribution in the pulmonary arteries with Glenn/Fontan circulation. METHODS: Magnetic resonance phase-contrast imaging was used to evaluate stroke volume index (SVI) in the left and right pulmonary arteries in patients with Glenn/Fontan circulation with unilateral DP. Data for 18 patients with univentricular heart and unilateral DP were analysed, 8 in the Glenn stage and 10 in the Fontan stage. Ten patients had right-sided DP, and 8 had left-sided DP. A diaphragmatic plication was performed in 7 patients. The control group consisted of 36 patients with Glenn (n = 16)/Fontan (n = 20) circulation without DP. RESULTS: In both left- and right-sided DP, the SVI to the ipsilateral side was significantly lower than in controls [2.81 (1.45-4.50) ml/m2 left vs 11.97 (7.36-16.37) ml/m2 in controls, P < 0.0002; 8.2 (4.49-12.64) ml/m2 with right vs 12.64 (9.66-16.61) ml/m2 in controls; P = 0.0284]. The SVI to the contralateral side showed a slight but non-significant increase in the presence of unilateral DP. CONCLUSIONS: Unilateral DP in patients with Glenn/Fontan circulation has a negative impact on pulmonary arterial SVI on the side of the paralysis.
引用
- Kratz T, Gaukstern L, Wiebe W, et al. Pulmonary blood flow in children with univentricular heart and unilateral diaphragmatic paralysis. Interdiscip Cardiovasc Thorac Surg. 2024. PMID: 38216538. doi:10.1093/icvts/ivae011
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。