该单中心回顾性队列研究纳入28例新生儿,在心脏术后72小时内监测脑氧饱和度指数(COx)等脑自动调节指标。术后发生急性神经事件者较未发生者的COx更高(0.16 vs 0.07,P=0.035)、COx>0.3时间占比更高(39.4% vs 29.2%,P=0.017)、平均动脉压低于自动调节下限时间占比更高(13.3% vs 6.9%,P=0.048)。

要点

  • 术后72小时COx监测可检出脑自动调节受损,整体COx>0.3时间占比中位数31.6%。
  • 发生术后急性神经事件的新生儿COx及COx>0.3时间占比均高于未发生者。
  • 不同先天性心脏缺陷亚组间脑自动调节指标未见差异。

核心结论

  • 心脏术后COx监测可检出脑自动调节受损,且该受损在发生术后急性神经事件的新生儿中更常见。

研究设计与样本

  • 单中心回顾性观察研究,纳入28例心脏术后新生儿,监测术后前72小时。
  • 分析存档数据计算脑氧饱和度指数(COx)及衍生指标,急性神经事件通过电子病历回顾识别。

主要发现

  • 28例中7例(25%)为左心发育不良综合征,21例(75%)为大动脉转位。
  • 整体COx>0.3(脑自动调节受损)时间占比中位数为31.6%(四分位距21.1%-38.3%)。
  • 不同心脏缺陷亚组间脑自动调节指标未见差异。
  • 7例(25%)发生术后急性神经事件。
  • 发生急性神经事件者较未发生者COx更高(0.16 vs 0.07,P=0.035)、COx>0.3时间占比更高(39.4% vs 29.2%,P=0.017)、平均动脉压低于自动调节下限时间占比更高(13.3% vs 6.9%,P=0.048)。

关键数值与推荐

  • 脑自动调节受损定义为COx>0.3的时间百分比。
  • 组间比较采用Mann-Whitney U检验,时间演变分析采用Skillings-Mack检验和Wilcoxon符号秩检验。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To investigate whether cerebral autoregulation is impaired after neonatal cardiac surgery and whether changes in autoregulation metrics are associated with different congenital heart defects or the incidence of postoperative neurologic events. METHODS: This is a retrospective observational study of neonates undergoing monitoring during the first 72 hours after cardiac surgery. Archived data were processed to calculate the cerebral oximetry index (COx) and derived metrics. Acute neurologic events were identified by an electronic medical record review. The Skillings-Mack test and the Wilcoxon signed-rank test were used to analyze the evolution of autoregulation metrics over time; the Mann-Whitney U test was used for comparison between groups. RESULTS: We included 28 neonates, 7 (25%) with hypoplastic left heart syndrome and 21 (75%) with transposition of the great arteries. Overall, the median percentage of time spent with impaired autoregulation, defined as percentage of time with a COx >0.3, was 31.6% (interquartile range, 21.1%-38.3%). No differences in autoregulation metrics between different cardiac defects subgroups were observed. Seven patients (25%) experienced a postoperative acute neurologic event. Compared to the neonates without an acute neurologic event, those with an acute neurologic event had a higher COx (0.16 vs 0.07; P = .035), a higher percentage of time with a COx >0.3 (39.4% vs 29.2%; P = .017), and a higher percentage of time with a mean arterial pressure below the lower limit of autoregulation (13.3% vs 6.9%; P = .048). CONCLUSIONS: COx monitoring after cardiac surgery allowed for the detection of impaired cerebral autoregulation, which was more frequent in neonates with postoperative acute neurologic events.