文献速递心外重症与机械循环支持

侧开胸入路能否在HeartMate 3植入后保留右心室功能?

Does lateral approach preserve the right ventricular function after HeartMate 3 insertion?
PubMed 文献 · Interdiscip Cardiovasc Thorac Surg · 2023-01-01

该回顾性研究纳入195例接受HeartMate 3植入的患者,其中55例(28%)经侧开胸入路、140例(72%)经正中开胸入路。术后1个月侧开胸组右心室舒张末内径和面积更小、右心室面积变化分数和收缩期峰值组织速度更高,但两组2年生存率和不良事件率无显著差异。

要点

  • 侧开胸组55例(28%),正中开胸组140例(72%),术前右心室几何形态和功能无显著差异。
  • 术后1个月侧开胸组右心室舒张末内径和面积更小,面积变化分数和收缩期峰值组织速度更高。
  • 两组2年生存率(93% vs 83%,P=0.28)和不良事件率(76% vs 71%,P=0.65)无显著差异。

核心结论

  • 侧开胸入路在术后1个月获得更好的右心室功能保留,但两组2年生存率和不良事件率无显著差异。

研究设计与样本

  • 回顾性研究,纳入接受HeartMate 3植入的患者195例,其中侧开胸组55例(28%),正中开胸组140例(72%)。
  • 在左心室辅助装置植入前、术后1个月和术后1年通过超声心动图评估右心室功能。
  • 主要结局为全因死亡,次要结局为因右心衰竭导致的死亡或再入院的复合终点。

主要发现

  • 术后1个月,侧开胸组右心室舒张末内径为42(29-48)mm,正中开胸组为47(42-52)mm,P=0.003。
  • 术后1个月,侧开胸组右心室舒张末面积为25(21-28)cm²,正中开胸组为29(24-36)cm²,P<0.001。
  • 术后1个月,侧开胸组右心室面积变化分数为30(25-34)%,正中开胸组为28(23-31)%,P=0.04。
  • 术后1个月,侧开胸组收缩期峰值组织速度为8(7-9)cm/s,正中开胸组为7(6-8)cm/s,P=0.01。
  • 24例患者死亡,46例达到复合终点;侧开胸组与正中开胸组2年生存率分别为93%和83%(log-rank检验,P=0.28),不良事件率分别为76%和71%(log-rank检验,P=0.65),均无显著差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Lateral thoracotomy (LT) approach may preserve the right ventricular (RV) function after left ventricular assist device (LVAD) implantation. This study evaluated the short- and long-term RV function using echocardiography after LVAD implantation via LT or median sternotomy (sternotomy). METHODS: The patients who underwent HeartMate 3 implantation were retrospectively reviewed. The RV function was assessed before and 1 month and 1 year after LVAD implantation. The primary and secondary outcomes were all-cause mortality and a composite of death or readmission due to RV failure, respectively. RESULTS: Of the 195 patients, 55 (28%) underwent LT and 140 (72%) underwent sternotomy. There were no significant differences in the preoperative RV geometry or function. One month after the LVAD implantation, the LT group had a smaller RV end-diastolic dimension [42 (29-48) vs 47 (42-52) mm; P = 0.003] and RV end-diastolic area [25 (21-28) vs 29 (24-36) cm2; P < 0.001] and a greater RV fractional area change [30 (25-34)% vs 28 (23-31)%; P = 0.04] and peak systolic tissue velocity [8 (7-9) vs 7 (6-8) cm/s; P = 0.01]. Twenty-four patients died and 46 met the composite end point. Kaplan-Meier curve analysis did not reveal significant differences between LT and sternotomy in the 2-year survival (93% vs 83%; log-rank test, P = 0.28) and adverse event rate (76% vs 71%; log-rank test, P = 0.65). CONCLUSIONS: LT approach yielded a better-preserved RV function at 1 month; however, there were no significant differences in the 2-year survival and adverse event rates.

来源:Interdiscip Cardiovasc Thorac Surg,查看原文。版权归原作者所有。

引用

  1. Hayashi H, Kirschner M, Vinogradsky A, et al. Does lateral approach preserve the right ventricular function after HeartMate 3 insertion? Interdiscip Cardiovasc Thorac Surg. 2023. PMID: 37824209. doi:10.1093/icvts/ivad168

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。