AVNeo瓣膜是否降低主动脉壁壁面剪切应力?基于4D-flow心脏磁共振评估Ozaki技术主动脉瓣置换的分析
前瞻性非随机临床试验纳入10例主动脉瓣新瓣叶成形术患者与10例生物瓣主动脉瓣置换患者,术后行4D-flow心脏磁共振并构建患者特异性计算流体动力学模型评估升主动脉壁面剪切应力。新瓣叶成形组在近端和远端升主动脉外弯段壁面剪切应力显著低于生物瓣置换组,校正射血分数和左心室流出道-主动脉角度后近端主动脉外弯段仍显著较低。作者认为新瓣叶成形术的血流动力学特征可能与较低的升主动脉壁面剪切应力相关。
要点
- 主动脉瓣新瓣叶成形组近端升主动脉外弯段壁面剪切应力显著低于生物瓣置换组(P=0.0179)。
- 远端升主动脉外弯段壁面剪切应力同样显著低于生物瓣置换组(P=0.0412)。
- 校正射血分数和左心室流出道-主动脉角度后,近端主动脉外弯段壁面剪切应力仍显著较低(P=0.02)。
核心结论
- 主动脉瓣新瓣叶成形术的血流动力学特征可能与较低的升主动脉壁面剪切应力相关,相比市售生物瓣膜。
研究设计与样本
- 前瞻性非随机临床试验,纳入10例接受主动脉瓣新瓣叶成形术患者与10例接受生物瓣主动脉瓣置换患者。
- 每位患者术后接受4D-flow心脏磁共振扫描,用于构建患者特异性计算流体动力学模型以评估升主动脉壁壁面剪切应力。
- 校正变量通过将多变量线性模型(以射血分数和左心室流出道-主动脉角度为协变量)的残差与变量均值相加计算。
主要发现
- 主动脉瓣新瓣叶成形组近端升主动脉外弯段壁面剪切应力显著低于主动脉瓣置换组(P=0.0179)。
- 主动脉瓣新瓣叶成形组远端升主动脉外弯段壁面剪切应力显著低于主动脉瓣置换组(P=0.0412)。
- 校正射血分数和左心室流出道-主动脉角度后,新瓣叶成形组近端主动脉外弯段壁面剪切应力仍显著较低[2.44 Pa(2.17-3.01) vs 1.94 Pa(1.72-2.01),P=0.02]。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Aortic valve neocuspidalization aims to replace the 3 aortic cusps with autologous pericardium pre-treated with glutaraldehyde, and it is a surgical alternative to the classical aortic valve replacement (AVR). Image-based patient-specific computational fluid dynamics allows the derivation of shear stress on the aortic wall [wall shear stress (WSS)]. Previous studies support a potential link between increased WSS and histological alterations of the aortic wall. The aim of this study is to compare the WSS of the ascending aorta in patients undergoing aortic valve neocuspidalization versus AVR with biological prostheses. METHODS: This is a prospective nonrandomized clinical trial. Each patient underwent a 4D-flow cardiac magnetic resonance scan after surgery, which informed patient-specific computational fluid dynamics models to evaluate WSS at the ascending aortic wall. The adjusted variables were calculated by summing the residuals obtained from a multivariate linear model (with ejection fraction and left ventricle outflow tract-aorta angle as covariates) to the mean of the variables. RESULTS: Ten patients treated with aortic valve neocuspidalization were enrolled and compared with 10 AVR patients. The aortic valve neocuspidalization group showed a significantly lower WSS in the outer curvature segments of the proximal and distal ascending aorta as compared to AVR patients (P = 0.0179 and 0.0412, respectively). WSS levels remained significantly lower along the outer curvature of the proximal aorta in the aortic valve neocuspidalization population, even after adjusting the WSS for the ejection fraction and the left ventricle outflow tract-aorta angle [2.44 Pa (2.17-3.01) vs 1.94 Pa (1.72-2.01), P = 0.02]. CONCLUSIONS: Aortic valve neocuspidalization hemodynamical features are potentially associated with a lower WSS in the ascending aorta as compared to commercially available bioprosthetic valves.
引用
- Pirola S, Pirola S, Mastroiacovo G, et al. Does the AVNeo valve reduce wall stress on the aortic wall? A cardiac magnetic resonance analysis with 4D-flow for the evaluation of aortic valve replacement with the Ozaki technique. Eur J Cardiothorac Surg. 2023. PMID: 37656941. doi:10.1093/ejcts/ezad299
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。