文献速递心外重症与机械循环支持

术前左心室舒张末期内径指数与HeartMate 3植入后结局相关

Preoperative left ventricular diastolic dimension index is associated with outcomes after HeartMate 3 implantation.
PubMed 文献 · Eur J Cardiothorac Surg · 2023-01-01

该回顾性研究分析了2014年11月至2021年9月在本中心植入HeartMate 3的253例患者,其中252例(99.6%)有左心室舒张末期内径指数数据。以33.5 mm/m²为截断值分组,较小左心室舒张末期内径指数组3年生存率(74% vs 88%,log-rank P=0.009)及无不良事件生存率(55% vs 73%,log-rank P=0.005)均更差,且与复合终点独立相关(HR 2.24,P=0.002)。

要点

  • 左心室舒张末期内径指数≤33.5 mm/m²组3年生存率74%,>33.5 mm/m²组88%(log-rank P=0.009)。
  • 左心室舒张末期内径指数≤33.5 mm/m²组3年无不良事件生存率55%,>33.5 mm/m²组73%(log-rank P=0.005)。
  • 较小左心室舒张末期内径指数与复合终点独立相关(HR 2.24,P=0.002)。

核心结论

  • 术前较小的左心室舒张末期内径指数与HeartMate 3植入术后更差的结局相关。

研究设计与样本

  • 回顾性研究,纳入2014年11月至2021年9月在本中心植入HeartMate 3的患者253例,其中252例(99.6%)有左心室舒张末期内径指数测量值。

主要发现

  • 以左心室舒张末期内径指数33.5 mm/m²为截断值分组:≤33.5 mm/m²组131例,>33.5 mm/m²组121例。
  • 两组年龄、INTERMACS分级和术前血流动力学无显著差异。
  • 较小左心室舒张末期内径指数组体表面积更大(2.1 vs 1.9 m²,P<0.001),缺血性心肌病比例更高[64例(49%)vs 40例(33%),P=0.01],左心房容积指数更小[40.5(32.3-54.0)ml/m² vs 54.0(43.0-66.8)ml/m²,P<0.001]。
  • 较小左心室舒张末期内径指数组3年生存率更差(74% vs 88%,log-rank P=0.009),3年无不良事件生存率更差(55% vs 73%,log-rank P=0.005)。
  • 较小左心室舒张末期内径指数与复合终点独立相关(HR 2.24,P=0.002)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: We investigated the association between indexed left ventricular diastolic dimension and clinical outcomes after HeartMate 3 implantation. METHODS: We retrospectively reviewed patients implanted with the HeartMate 3 at our centre between November 2014 and September 2021. Left ventricular diastolic dimension was assessed via preoperative transthoracic echocardiography and left ventricular diastolic dimension index was calculated as left ventricular diastolic dimension/body surface area. The primary outcome was a composite of death or readmission due to right heart failure or stroke. The cut-off left ventricular diastolic dimension index value most closely associated with outcomes was determined by receiver-operating characteristic curve and restricted cubic spline analyses. RESULTS: Left ventricular diastolic dimension index measurements were available for 252 of 253 (99.6%) patients. Using a left ventricular diastolic dimension index cut-off value of 33.5 mm/m2, the cohort was divided: left ventricular diastolic dimension index ≤ (n = 131) or > (n = 121) 33.5 mm/m2. While there were no significant differences in age, INTERMACS level and preoperative haemodynamics between groups, patients with smaller left ventricular diastolic dimension index were more likely to have a larger body surface area (2.1 vs 1.9 m2, P < 0.001), ischaemic cardiomyopathy [64 (49%) vs 40 (33%), P = 0.01] and smaller left atrium volume index [40.5 (32.3-54.0) ml/m2 vs 54.0 (43.0-66.8) ml/m2, P < 0.001]. Smaller left ventricular diastolic dimension index patients had significantly worse survival (74% vs 88%, log-rank P = 0.009) and freedom from adverse events (55% vs 73%, log-rank P = 0.005) at 3-year follow-up. Smaller left ventricular diastolic dimension index was independently associated with the composite outcome (Hazard ratio 2.24, P = 0.002). CONCLUSIONS: Smaller preoperative left ventricular diastolic dimension index is associated with worse outcomes in patients undergoing HeartMate 3 implantation.

来源:Eur J Cardiothorac Surg,查看原文。版权归原作者所有。

引用

  1. Vinogradsky AV, Hayashi H, Kirschner M, et al. Preoperative left ventricular diastolic dimension index is associated with outcomes after HeartMate 3 implantation. Eur J Cardiothorac Surg. 2023. PMID: 37589647. doi:10.1093/ejcts/ezad287

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。