Epithor转换评分在机器人辅助解剖性肺切除术中可靠吗
该回顾性单中心研究纳入2006年1月至2022年6月EPITHOR数据库中行解剖性肺切除的患者,比较Epithor转换评分(ECS)在电视辅助胸腔镜手术(VATS)与机器人辅助胸腔镜手术(RATS)中的区分度和校准度。结果显示RATS组转换率6.9%(27/386),VATS组14.1%(183/1299);RATS组曲线下面积0.66 [0.56-0.78],VATS组0.64 [0.60-0.69];Hosmer-Lemeshow检验两组均不显著,VATS组P=0.12,RATS组P=0.08。结论认为ECS似乎适用于RATS患者,区分度正确但校准度较VATS患者低,可开发新评分专门预测RATS转换。
要点
- RATS组转换率6.9%(27/386),VATS组14.1%(183/1299)。
- RATS组曲线下面积0.66 [0.56-0.78],VATS组0.64 [0.60-0.69]。
- Hosmer-Lemeshow检验VATS组P=0.12,RATS组P=0.08,两组均不显著。
核心结论
- ECS似乎适用于RATS患者,区分度正确但校准度较VATS患者低。
- 可开发新评分专门预测RATS患者的转换。
研究设计与样本
- 回顾性单中心研究,数据来自EPITHOR数据库,时间范围为2006年1月至2022年6月。
- 纳入行解剖性肺切除的VATS或RATS患者,共1685例,其中VATS组1299例,RATS组386例。
- 对所有患者计算ECS,采用曲线下面积评估区分度,Hosmer-Lemeshow检验评估校准度。
主要发现
- VATS组转换183/1299例(14.1%),RATS组转换27/386例(6.9%)。
- RATS组抗血小板治疗和外周动脉疾病较少,VATS组肺段切除术较多。
- RATS组曲线下面积0.66 [0.56-0.78],VATS组0.64 [0.60-0.69]。
- Hosmer-Lemeshow检验两组均不显著,VATS组P=0.12,RATS组P=0.08。
关键数值与推荐
- ECS在RATS组的曲线下面积为0.66 [0.56-0.78],在VATS组为0.64 [0.60-0.69]。
- Hosmer-Lemeshow检验VATS组P=0.12,RATS组P=0.08。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Despite an improvement in surgical abilities, the need for an intraoperative switch from a minimally invasive procedure towards an open surgery (conversion) still remains. To anticipate this risk, the Epithor conversion score (ECS) has been described for video-assisted thoracoscopic surgery (VATS). Our objective was to determine if this score, developed for VATS, is applicable in robotic-assisted thoracoscopic surgery (RATS). METHODS: This was a retrospective monocentric study from January 2006 to June 2022, and data were obtained from the EPITHOR database. Patients included were those who underwent anatomic lung resection either by VATS or RATS. The ECS was calculated for all patients studied. Discrimination and calibration of the test were measured by the area under the curve and Hosmer-Lemeshow test. RESULTS: A total of 1685 were included. There were 183/1299 conversions in the VATS group (14.1%) and 27/386 conversions in the RATS group (6.9%). Patients in the RATS group had fewer antiplatelet therapy and peripheral arterial disease. There were more segmentectomies in the VATS group. As for test discrimination, the area under the curve was 0.66 [0.56-0.78] in the RATS group and 0.64 [0.60-0.69] in the VATS group. Regarding the calibration, the Hosmer-Lemeshow test was not significant for both groups but more positive (better calibrated) for the VATS group (P = 0.12) compared to the RATS group (P = 0.08). CONCLUSIONS: The ECS seems applicable for patients operated with RATS, with a correct discrimination but a lower calibration performance for patients operated with VATS. A new score could be developed to specifically anticipate conversion in patients operated on by RATS.
引用
- Armand E, Fourdrain A, Lafouasse C, et al. Is the Epithor conversion score reliable in robotic-assisted surgery anatomical lung resection? Eur J Cardiothorac Surg. 2023. PMID: 37584685. doi:10.1093/ejcts/ezad283
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。