文献速递主动脉外科

半定制一体式单分支覆膜支架在既往2区胸主动脉腔内修复术中的解剖可行性

Anatomical feasibility of a 'semi-custom' unibody single-branch endograft in previous zone 2 thoracic endovascular aortic repair.
PubMed 文献 · Eur J Cardiothorac Surg · 2023-01-01

这项单中心回顾性队列研究纳入1999至2022年间在2区锚定区接受胸主动脉腔内修复术且有术前CT血管造影的72例患者,评估Castor覆膜支架的解剖可行性。49例(68.1%)适合植入Castor支架,75%的可植入患者需21种配置,采用较宽松标准可降至12种配置。

要点

  • 在2区锚定区接受胸主动脉腔内修复术的72例患者中,49例(68.1%)解剖上适合Castor覆膜支架。
  • 治疗75%的可植入患者需要21种支架配置,采用较宽松标准可降至12种配置。
  • 左颈总动脉与左锁骨下动脉间平均距离12.4 ± 5.2 mm,平均直径33.0 ± 10.6 mm。

核心结论

  • Castor覆膜支架在部分需在2区锚定区行胸主动脉腔内修复术的患者中解剖可行。
  • 四分之三的可植入患者可通过合理数量的配置进行治疗,为未来即用型应用铺路。

研究设计与样本

  • 这是一项临床前、单中心、真实世界、全人群、回顾性队列研究。
  • 纳入1999至2022年间在2区锚定区接受胸主动脉腔内修复术且有术前CT血管造影的患者,共473例手术中72例符合纳入标准。

主要发现

  • 左颈总动脉与左锁骨下动脉(或无名动脉与牛型干)间平均距离为12.4 ± 5.2 mm,平均直径为33.0 ± 10.6 mm。
  • 左锁骨下动脉椎前段直径和长度分别为11.3 ± 2.5 mm和38.7 ± 10.8 mm。
  • 49例(68.1%)患者适合Castor植入。
  • 治疗75%的可植入患者需要21种配置,采用较宽松标准可降至12种配置。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: The aim of this study was to evaluate the suitability of a subclavian unibody single-branch endograft among patients treated with thoracic endovascular aortic repair (TEVAR) in landing zone 2 (LZ2). METHODS: This is a pre-clinical, single-centre, real-world, all-comers, retrospective cohort study. Patients treated with TEVAR in LZ2 with an available preoperative computed tomography angiography were included. The primary outcome was the anatomical feasibility of the Castor endograft in patients receiving endovascular treatment in LZ2 between 1999 and 2022. Secondary outcomes were: a comparison of feasible and unfeasible patients; frequencies and description of exclusion causes; non-feasibility risk factor analysis; and analysis of the stent graft configurations necessary to treat 75% of the patients. A logistic regression model was used to find associations between baseline morphological data and non-feasibility. RESULTS: A total of 473 procedures were performed and 72 patients fulfilling inclusion criteria were included. The mean distance between the left carotid artery and left subclavian artery (or between innominate artery and bovine trunk) was 12.4 ± 5.2 mm and its average diameter was 33.0 ± 10.6 mm. The pre-vertebral left subclavian artery's diameter and length were 11.3 ± 2.5 and 38.7 ± 10.8 mm. Forty-nine (68.1%) patients were suitable for Castor implantation. Twenty-one configurations were required to treat 75% of feasible patients and might be lowered to 12 configurations applying less strict criteria. CONCLUSIONS: The Castor endograft was anatomically feasible in several patients requiring TEVAR in LZ2. Three-quarters of feasible patients could be treated with a reasonable number of configurations, paving the path for future off-the-shelf applications.

来源:Eur J Cardiothorac Surg,查看原文。版权归原作者所有。

引用

  1. Leone N, Andreoli F, Bartolotti LAM, et al. Anatomical feasibility of a 'semi-custom' unibody single-branch endograft in previous zone 2 thoracic endovascular aortic repair. Eur J Cardiothorac Surg. 2023. PMID: 37603731. doi:10.1093/ejcts/ezad290