肺动脉不同钳夹技术的实验与组织学评估
本研究在体外模型和人体肺动脉标本中比较双环技术、DeBakey钳等五种钳夹方式的耐压能力与内膜损伤。实验显示双环技术与DeBakey钳第三齿的爆破压和最大钳夹压力无显著差异,组织学研究显示两者爆破压无显著差异,双环技术仅致内膜变形。
要点
- 双环技术与DeBakey钳第三齿的爆破压无显著差异(24.6±2.8 vs 21.8±2.8 mmHg,P=0.094)。
- 双环技术与DeBakey钳第三齿的最大钳夹压力无显著差异(1.54±0.12 vs 1.49±0.12 MPa,P=0.954)。
- 组织学研究中双环技术与DeBakey钳第三齿的爆破压无显著差异(P=0.754),双环技术仅致内膜变形。
核心结论
- 双环技术具有与DeBakey钳第三齿相似的耐压能力和内膜负荷,对于胸腔镜解剖性肺切除术是可行的。
研究设计与样本
- 实验研究使用聚乙烯醇主肺动脉模型、压力计和充放气装置测量爆破压,用压力测量膜测量最大钳夹压力,每种测量重复10次。
- 组织学研究测量人体肺动脉的爆破压并评估双环技术和DeBakey钳导致的内膜损伤。
主要发现
- 实验研究中双环技术与DeBakey钳第三齿的爆破压无显著差异(24.6±2.8 vs 21.8±2.8 mmHg,P=0.094)。
- 实验研究中双环技术与DeBakey钳第三齿的最大钳夹压力无显著差异(1.54±0.12 vs 1.49±0.12 MPa,P=0.954)。
- 组织学研究中双环技术与DeBakey钳第三齿的爆破压无显著差异(P=0.754)。
- 组织学研究中双环技术在每5个样本中仅导致内膜变形。
临床怎么用
- 作者认为双环技术对于胸腔镜解剖性肺切除术是可行的,因其耐压能力和内膜负荷与DeBakey钳第三齿相似。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: The double-loop technique has been used in our clinical settings for pulmonary arterioplasty and/or injured artery repair during thoracoscopic anatomical lung resection. We evaluated the pressure resistance capacity and intimal load to determine the effectiveness and safety of the double-loop technique. METHODS: The double-loop technique, DeBakey clamp, Fogarty clamp, endovascular clips and vessel loop technique were evaluated. During an experimental study, a polyvinyl alcohol main pulmonary artery model, manometer and in-deflation device were used to measure the burst pressure. The maximum clamp pressure was measured using a pressure-measuring film. Each measurement was performed 10 times. During the histological study, we measured the burst pressure and evaluated the intimal damage of the human pulmonary artery associated with the double-loop technique and DeBakey clamp. RESULTS: The experimental burst pressure (mmHg) and maximum clamp pressure (MPa) between the double-loop technique and DeBakey at the third notch were not significantly different (24.6 ± 2.8 and 21.8 ± 2.8, P = 0.094; 1.54 ± 0.12 and 1.49 ± 0.12, P = 0.954). During the histological study, the burst pressures of the double-loop technique and DeBakey at the third notch were also not significantly different (P = 0.754). Furthermore, the double-loop technique resulted in only intimal deformation in each five samples. CONCLUSIONS: The double-loop technique is feasible for thoracoscopic anatomical lung resection because it has similar pressure resistance capacity and intimal load as DeBakey at the 3rd notch.
引用
- Chiba Y, Takahashi Y, Takase Y, et al. Experimental and histological evaluation of different clamp technique for pulmonary artery. Interdiscip Cardiovasc Thorac Surg. 2023. PMID: 37522888. doi:10.1093/icvts/ivad119
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。