虚拟手术预测16毫米管道成人Fontan患者优化管道尺寸
本研究利用基于磁共振成像的计算流体动力学模型,对5例植入16毫米心外Fontan管道的成人患者进行虚拟扩大至24-32毫米,评估对总腔肺连接血流动力学和能量学的影响。虚拟扩大使TCPC压力梯度降低40-65%,但肺动脉仍是能量损失主要来源;管道内血流停滞体积和相对 residence 时间升高区域虽增加但仍可忽略,提示血栓风险可能较低。
要点
- 虚拟扩大16毫米管道至24-32毫米可使TCPC压力梯度降低40-65%。
- 扩大后肺动脉仍贡献总能量损失的60-73%。
- 血流停滞体积在静息时<2%、运动时<0.5%,高RRT面积静息<3%、运动<1%。
核心结论
- 基于患者特异性管道流量将16毫米管道虚拟扩大至24-32毫米,可显著改善TCPC效率,同时血栓风险推测仍较低。
研究设计与样本
- 基于磁共振成像的患者特异性TCPC计算流体动力学模拟模型,在静息和增加血流条件下进行。
- 共模拟5例植入16毫米心外Fontan连接的成人患者,虚拟扩大至24-32毫米。
主要发现
- 虚拟扩大使TCPC压力梯度降低40-65%,具体取决于虚拟管道尺寸。
- 尽管整个TCPC能量学改善,肺动脉仍是能量损失的重要贡献者,占总损失的60-73%。
- 管道扩大后,虚拟管道内血流停滞体积和相对 residence 时间(RRT)>20/Pa的体表面积增加,但仍可忽略:静息时血流停滞<2%管道体积,运动时<0.5%;高RRT面积静息<3%,运动<1%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Recent evidence suggests that conduits implanted in Fontan patients at the age of 2-4 years become undersized for adulthood. The objective of this study is to use computational fluid dynamic models to evaluate the effect of virtual expansion of the Fontan conduit on haemodynamics and energetics of the total cavopulmonary connection (TCPC) under resting conditions and increased flow conditions. METHODS: Patient-specific, magnetic resonance imaging-based simulation models of the TCPC were performed during resting and increased flow conditions. The original 16-mm conduits were virtually enlarged to 3 new sizes. The proposed conduit sizes were defined based on magnetic resonance imaging-derived conduit flow in each patient. Flow efficiency was evaluated based on power loss, pressure drop and resistance and thrombosis risk was based on flow stagnation volume and relative residence time (RRT). RESULTS: Models of 5 adult patients with a 16-mm extracardiac Fontan connection were simulated and subsequently virtually expanded to 24-32 mm depending on patient-specific conduit flow. Virtual expansion led to a 40-65% decrease in pressure gradient across the TCPC depending on virtual conduit size. Despite improved energetics of the entire TCPC, the pulmonary arteries remained a significant contributor to energy loss (60-73% of total loss) even after virtual surgery. Flow stagnation volume inside the virtual conduit and surface area in case of elevated RRT (>20/Pa) increased after conduit enlargement but remained negligible (flow stagnation <2% of conduit volume in rest, <0.5% with exercise and elevated RRT <3% in rest, <1% with exercise). CONCLUSIONS: Virtual expansion of 16-mm conduits to 24-32 mm, depending on patient-specific conduit flow, in Fontan patients significantly improves TCPC efficiency while thrombosis risk presumably remains low.
引用
- Hut T, Roest A, Gaillard D, et al. Virtual surgery to predict optimized conduit size for adult Fontan patients with 16-mm conduits. Interdiscip Cardiovasc Thorac Surg. 2023. PMID: 37522877. doi:10.1093/icvts/ivad126