肺动脉搏动指数在左心室辅助装置治疗中的系统综述与生理学
本系统综述检索PubMed、EMBASE、CENTRAL等数据库,纳入16项研究、共20634例植入耐久性左心室辅助装置(LVAD)的成人患者,评估肺动脉搏动指数(PAPi)与右心衰竭(RHF)及死亡的关系。结果显示较低的PAPi与RHF和死亡相关,但PAPi cutoff(0.88至3.3)依赖于肺血管阻力(PVR),无法定义单一cutoff。
要点
- 较低的PAPi与LVAD植入后右心衰竭和死亡相关。
- 6项研究报告的PAPi cutoff范围为0.88至3.3。
- PAPi cutoff与肺血管阻力直接相关(r=0.6613,P=0.019)。
核心结论
- 较低的PAPi与LVAD植入后RHF和死亡相关,但无法定义单一PAPi cutoff,因其依赖于PVR。
研究设计与样本
- 系统综述,检索PubMed、EMBASE、CENTRAL并手动筛选参考文献,纳入报告成人耐久性LVAD患者PAPi的临床研究,2名评价者独立筛选和提取数据,采用纽卡斯尔-渥太华量表评估非随机研究质量,研究在PROSPERO前瞻性注册(CRD42021259009)。
- 从283条唯一记录中纳入16项研究,共20634例植入耐久性LVAD的成人患者。
主要发现
- 仅2项研究报告死亡率,两项研究中较低的PAPi均与死亡显著相关。
- 15项研究报告RHF数据,其中10项研究中较低的PAPi与RHF显著相关。
- 6项研究报告PAPi cutoff范围为0.88至3.3,cutoff与PVR直接相关(r=0.6613,P=0.019)。
关键数值与推荐
- PAPi cutoff范围为0.88至3.3。
- PAPi cutoff与PVR直接相关(r=0.6613,P=0.019)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Right heart failure (RHF) is a major complication following left ventricular assist device (LVAD) implantation. Pulmonary artery pulsatility index (PAPi) has been evaluated as a haemodynamic marker for RHF, but PAPi is dependent on pulmonary vascular resistance (PVR). We conducted a systematic review to assess the relationship between PAPi and RHF and death in patients undergoing LVAD implantation and examined the relationship between PAPi cut-off and PVR. METHODS: We searched PubMed, EMBASE, CENTRAL and manually screened retrieved references to identify all clinical studies reporting PAPi in adult patients with a durable LVAD. Eligibility criteria were prespecified and 2 reviewers independently screened and extracted data; the Newcastle-Ottawa Scale was used to assess quality of non-randomized studies. This study was prospectively registered on PROSPERO (CRD42021259009). RESULTS: From 283 unique records, we identified 16 studies reporting haemodynamic assessment in 20 634 adult patients with an implanted durable LVAD. Only 2 studies reported on mortality and in both, a lower PAPi was significantly associated with death. Fifteen studies reported RHF data and, in 10 studies, a lower PAPi was significantly associated with RHF. Six studies reported on PAPi cut-offs ranging from 0.88 to 3.3; and the cut-offs were directly related to PVR (r = 0.6613, P = 0.019). CONCLUSIONS: Lower PAPi was associated with RHF and death following LVAD implantation, but a single PAPi cut-off cannot be defined, as it is dependent on PVR.
引用
- Yim IHW, Khan-Kheil AM, Drury NE, et al. A systematic review and physiology of pulmonary artery pulsatility index in left ventricular assist device therapy. Interdiscip Cardiovasc Thorac Surg. 2023. PMID: 37171900. doi:10.1093/icvts/ivad068