循环死亡后供体胸腹常温区域灌注未恢复脑血流
该研究在2例循环死亡后供体胸腹常温区域灌注(TA-NRP)过程中使用术中经颅多普勒(TCD)评估脑血流。两例在拔管前均存在前后循环脑血流波形,宣告死亡并启动TA-NRP后均未检测到脑血流,同时脑干反射消失、对伤害性刺激无反应且无呼吸努力。TCD结果提示DCD联合TA-NRP未恢复脑血流。
要点
- 两例DCD TA-NRP中,拔管前TCD可检测到前、后循环脑血流波形。
- 宣告死亡并启动TA-NRP后,两例均未检测到脑血流。
- 两例均无脑干反射、对伤害性刺激无反应及无呼吸努力。
核心结论
- TCD结果表明,循环死亡后供体胸腹常温区域灌注未恢复脑血流。
研究设计与样本
- 在2例循环死亡后供体胸腹常温区域灌注(TA-NRP)病例中使用术中经颅多普勒(TCD)评估脑血流。
- 以1例接受心胸外科手术的机械循环支持患者作为对照,其TCD波形用于比较。
主要发现
- 拔管前,两例DCD TA-NRP病例均存在前、后循环脑血流波形,与对照患者检测到的波形相似。
- 宣告死亡并启动TA-NRP后,两例均未检测到脑血流。
- 两例均无脑干反射、对伤害性刺激无反应且无呼吸努力。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Use of thoracoabdominal normothermic regional perfusion (TA-NRP) during donation after circulatory death (DCD) is an important advance in organ donation. Prior to establishing TA-NRP, the brachiocephalic, left carotid, and left subclavian arteries are ligated, thereby eliminating anterograde brain blood flow via the carotid and vertebral arteries. While theoretical concerns have been voiced that TA-NRP after DCD may restore brain blood flow via collaterals, there have been no studies to confirm or refute this possibility. We evaluated brain blood flow using intraoperative transcranial Doppler (TCD) in two DCD TA-NRP cases. Pre-extubation, anterior and posterior circulation brain blood flow waveforms were present in both cases, similar to the waveforms detected in a control patient on mechanical circulatory support undergoing cardiothoracic surgery. Following declaration of death and initiation of TA-NRP, no brain blood flow was detected in either case. Additionally, there was absence of brainstem reflexes, no response to noxious stimuli and no respiratory effort. These TCD results demonstrate that DCD with TA-NRP did not restore brain blood flow.
引用
- Frontera JA, Lewis A, James L, et al. Thoracoabdominal normothermic regional perfusion in donation after circulatory death does not restore brain blood flow. J Heart Lung Transplant. 2023. PMID: 37211334. doi:10.1016/j.healun.2023.05.010
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。