文献速递瓣膜外科

基于影像的二尖瓣修复成形环尺寸预测

Image-based ring size prediction for mitral valve repair.
PubMed 文献 · Eur J Cardiothorac Surg · 2023-01-01

本研究纳入150例因Carpentier II型病变行微创二尖瓣修复并置入成形环、出院时无或微量残余二尖瓣反流的患者,用半自动软件(4D MV Analysis)构建三维二尖瓣重建模型量化二尖瓣几何,通过单因素和多因素线性回归预测成形环尺寸。结果显示交界宽度(CW)与植入环尺寸相关性最高(r=0.839,P<0.001),多因素分析仅CW和ITD为独立预测因子(R²=0.743,P<0.001),76.6%患者预测环尺寸与实际环尺寸差异不超过1个型号。

要点

  • 三维二尖瓣重建模型预测成形环尺寸,CW与植入环尺寸相关性最高(r=0.839,P<0.001)。
  • 多因素回归仅CW和ITD为独立预测因子(R²=0.743,P<0.001)。
  • 76.6%患者预测环尺寸与实际环尺寸差异不超过1个型号。

核心结论

  • 三维二尖瓣重建模型可支持外科医生在成形环尺寸选择中的决策过程。
  • 本研究可能是利用多模态机器学习决策支持实现准确成形环尺寸预测的第一步。

研究设计与样本

  • 纳入150例因Carpentier II型病变行微创二尖瓣修复并置入成形环、出院时无或微量残余二尖瓣反流的患者。
  • 使用半自动软件包(4D MV Analysis)构建三维二尖瓣重建模型以量化二尖瓣几何。
  • 采用单因素和多因素线性回归分析预测成形环尺寸。

主要发现

  • 三维二尖瓣重建值与植入环尺寸之间,交界宽度(CW)相关系数最高(0.839;P<0.001)。
  • 间三角距离(ITD)相关系数为0.796(P<0.001),瓣环面积为0.782(P<0.001),前二尖瓣叶面积为0.767(P<0.001),前后径为0.679(P<0.001),前二尖瓣叶长度为0.515(P<0.001)。
  • 多因素回归分析中仅CW和ITD为成形环尺寸的独立预测因子(R²=0.743;P<0.001)。
  • CW和ITD的一致性最高,76.6%患者接受的环尺寸与预测环尺寸差异不超过1个型号。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Annuloplasty rings are routinely used in mitral valve repair (MVr). However, accurate annuloplasty ring size selection is essential to obtain a favourable outcome. Moreover, ring sizing can be challenging in some patients and is highly influenced by surgeons' experience. This study investigated the utility of three-dimensional mitral valve (3D-MV) reconstruction models to predict annuloplasty ring size for MVr. METHODS: A total of 150 patients undergoing minimally invasive MVr with annuloplasty ring due to Carpentier type II pathology and who were discharged with none/trace residual mitral regurgitation were included. 3D-MV reconstruction models were created with a semi-automated software package (4D MV Analysis) to quantitate mitral valve geometry. To predict the ring size, univariable and multivariable linear regression analyses were performed. RESULTS: Between 3D-MV reconstruction values and implanted ring sizes, the highest correlation coefficients were provided by commissural width (CW) (0.839; P < 0.001), intertrigonal distance (ITD) (0.796; P < 0.001), annulus area (0.782; P < 0.001), anterior mitral leaflet area (0.767; P < 0.001), anterior-posterior diameter (0.679; P < 0.001) and anterior mitral leaflet length (0.515; P < 0.001). In multivariable regression analysis, only CW and ITD were found to be independent predictors of annuloplasty ring size (R2 = 0.743; P < 0.001). The highest level of agreement was achieved with CW and ITD, and 76.6% of patients received a ring with no >1 ring size difference from the predicted ring sizes. CONCLUSIONS: 3D-MV reconstruction models can support surgeons in the decision-making process for annuloplasty ring sizing. The present study may be a first step towards accurate annuloplasty ring size prediction using multimodal machine learning decision support.

来源:Eur J Cardiothorac Surg,查看原文。版权归原作者所有。

引用

  1. Akansel S, Kofler M, Van Praet KM, et al. Image-based ring size prediction for mitral valve repair. Eur J Cardiothorac Surg. 2023. PMID: 37233202. doi:10.1093/ejcts/ezad212

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。