低 Profile 支架移植物降低毛主动脉患者胸主动脉腔内修复术中栓塞风险
LPSG组总栓塞事件率显著低于CSSG组(0/35 [0%] vs 34/312 [11.2%],P=0.035),毛主动脉(odds ratio: 5.220; P<0.001)为栓塞事件阳性预测因素;在68例毛主动脉患者中,LPSG组总栓塞事件率显著低于CSSG组(0/12 [0%] vs 19/56 [34%],P=0.015),而在279例非毛主动脉患者中两组无差异(0 [0%] vs 16 [6.3%],P=0.377)。结论认为LPSG使用可减少胸主动脉腔内修复术中的栓塞,在毛主动脉患者中差异更明显,LPSG可能有益于预防毛主动脉患者胸主动脉腔内修复术中的栓塞。
要点
- LPSG组总栓塞事件率显著低于CSSG组(0/35 [0%] vs 34/312 [11.2%],P=0.035)。
- 毛主动脉为栓塞事件阳性预测因素(odds ratio: 5.220; P<0.001)。
- 毛主动脉患者中LPSG组总栓塞事件率显著低于CSSG组(0/12 [0%] vs 19/56 [34%],P=0.015)。
核心结论
- LPSG使用可减少胸主动脉腔内修复术中的栓塞,且在毛主动脉患者中差异更明显;LPSG可能有益于预防毛主动脉患者胸主动脉腔内修复术中的栓塞。
研究设计与样本
- 回顾性研究,纳入2009至2021年35例接受LPSG的胸主动脉腔内修复术患者(27例男性;年龄77±9.2岁)和312例接受CSSG的胸主动脉腔内修复术患者(247例男性;年龄77±7.4岁),均为非夹层远端弓及降主动脉胸主动脉瘤。
主要发现
- LPSG组总栓塞事件率为0/35(0%),CSSG组为34/312(11.2%),LPSG组显著低于CSSG组(P=0.035)。
- 毛主动脉为栓塞事件的阳性预测因素(odds ratio: 5.220; P<0.001)。
- 68例毛主动脉患者中(LPSG组12例,CSSG组56例),LPSG组总栓塞事件率为0/12(0%),CSSG组为19/56(34%),LPSG组显著低于CSSG组(P=0.015)。
- 279例非毛主动脉患者中(LPSG组23例,CSSG组256例),LPSG组总栓塞事件率为0(0%),CSSG组为16(6.3%),两组间无差异(P=0.377)。
临床怎么用
- 作者认为LPSG使用可减少胸主动脉腔内修复术中的栓塞,且在毛主动脉患者中差异更明显;LPSG可能有益于预防毛主动脉患者胸主动脉腔内修复术中的栓塞。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: This study aimed to reveal the association between lower-profile stent graft (LPSG) and embolism during thoracic endovascular aortic repair for non-dissecting distal arch and descending thoracic aortic aneurysm. METHODS: This study reviewed data of 35 patients who underwent thoracic endovascular aortic repair with LPSG (27 males; age: 77 ± 9.2 years) and 312 who underwent thoracic endovascular aortic repair with conventional-sized stent graft (CSSG) (247 males; age: 77 ± 7.4 years) from 2009 to 2021. RESULTS: The rate of total embolic events was significantly lower in the LPSG group (0/35 [0%]) than the CSSG group (34/312 [11.2%]) (P = 0.035). Shaggy aorta (odds ratio: 5.220; P < 0.001) were identified as positive embolic event predictors. The rate of total embolic events in 68 patients with shaggy aorta (12 in LPSG/56 in CSSG) was significantly lower in the LPSG group (0/12 [0%]) than the CSSG group (19/56 [34%]) (P = 0.015). The rate of total embolic events in 279 patients with the non-shaggy aorta (23 in LPSG/256 in CSSG) reveals no difference between the 2 groups (0 [0%]/16 [6.3%]) (P = 0.377). CONCLUSIONS: LPSG usage could reduce embolism in thoracic endovascular aortic repair, and the difference was more pronounced in patients with the shaggy aorta. LPSG might be beneficial in preventing embolism in thoracic endovascular aortic repair for patients with a shaggy aorta.
引用
- Seike Y, Masada K, Fukuda T, et al. Lower-profile stent graft reduces the risk of embolism during thoracic endovascular aortic repair in shaggy aorta. Interdiscip Cardiovasc Thorac Surg. 2023. PMID: 37094223. doi:10.1093/icvts/ivad058
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。