文献速递先天性心脏病外科瓣膜外科

手工缝合心包瓣膜肺动脉管道:体外搏动流环路与猪急性在体评估

A handsewn pericardial valved pulmonary conduit: pulsatile flow loop in vitro and acute porcine in vivo evaluation.
PubMed 文献 · Eur J Cardiothorac Surg · 2023-01-01

研究在体外搏动流环路和60 kg猪急性在体模型中评估手工缝合戊二醛处理心包瓣膜肺动脉管道替代肺动脉瓣的效果。体外4 L/min和7 L/min及在体条件下瓣膜均临床功能充足,跨瓣压差在可接受范围,早期未见管道结构损伤证据。

要点

  • 手工缝合心包瓣膜肺动脉管道可在手术台上制作并易于缝合固定。
  • 体外和急性猪在体实验中所有瓣膜均临床功能充足。
  • 早期未见管道结构损伤证据,流体动力学数据可接受。

核心结论

  • 概念验证研究显示手工缝合心包瓣膜肺动脉管道早期无结构损伤证据,流体动力学数据可接受。

研究设计与样本

  • 采用体外搏动流环路模型和60 kg猪急性在体模型进行概念验证研究。
  • 体外研究纳入15个肺动脉干在4 L/min下和13个肺动脉干在7 L/min下,在体研究纳入11只动物。

主要发现

  • 体外4 L/min时,自体瓣膜和管道平均跨瓣压差分别为8 mmHg(标准差2)和7 mmHg(标准差2)。
  • 体外7 L/min时,自体瓣膜和管道平均跨瓣压差分别为19 mmHg(标准差3)和17 mmHg(标准差4)。
  • 在体时,自体瓣膜和管道平均跨瓣压差分别为3 mmHg(标准差2)和6 mmHg(标准差3)。
  • 所有瓣膜在体外和在体均临床功能充足。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Right ventricle to pulmonary artery anatomic discontinuity is common in complex congenital heart malformations. Handsewn conduits are a practised method of repair. In a proof-of-concept study, we evaluated pulmonary valve replacement with a handsewn pericardial valved pulmonary conduit in vitro and in vivo. METHODS: A pulsatile flow-loop model (in vitro) and an acute 60-kg porcine model (in vivo) were used. With echocardiography and pressure catheters, baseline geometry and fluid dynamics were measured. The pulmonary valve was replaced with a handsewn glutaraldehyde-treated pericardial valved pulmonary conduit corresponding to a 21-mm prosthetic valve, after which geometric measurements and fluid dynamics were reassessed. RESULTS: In vitro, 15 pulmonary trunks at 4 l/min and 13 trunks at 7 l/min, and in vivo, 11 animals were investigated. The valved pulmonary conduit was straightforward to produce at the operating table and easy to suture in place. All valves were clinically sufficient in vitro and in vivo. The mean transvalvular pressure gradient in the native valve and the conduit was 8 mmHg [standard deviation (SD): 2] and 7 mmHg (SD: 2) at 4 l/min in vitro, 19 mmHg (SD: 3) and 17 mmHg (SD: 4) at 7 l/min in vitro and 3 mmHg (SD: 2) and 6 mmHg (SD: 3) in vivo. CONCLUSIONS: Our proof-of-concept demonstrates no early evidence of structural damage to the conduit, and the fluid dynamic data were acceptable. The handsewn conduit can be produced at the operating table.

来源:Eur J Cardiothorac Surg,查看原文。版权归原作者所有。

引用

  1. Carlson Hanse L, Tjørnild MJ, Karunanithi Z, et al. A handsewn pericardial valved pulmonary conduit: pulsatile flow loop in vitro and acute porcine in vivo evaluation. Eur J Cardiothorac Surg. 2023. PMID: 37042717. doi:10.1093/ejcts/ezad143