文献速递瓣膜外科

主动脉瓣叶撕裂对经导管主动脉瓣置换流体力学的影响及与外科主动脉瓣置换的比较

Effect of leaflet laceration on transcatheter aortic valve replacement fluid mechanics and comparison with surgical aortic valve replacement.
PubMed 文献 · J Thorac Cardiovasc Surg · 2023-03-11

该体外研究在模拟血流环路中比较了外科主动脉瓣置换(SAVR)与经导管主动脉瓣置换(TAVR)伴或不伴主动脉瓣叶撕裂时的窦部及新窦部流速与流型。SAVR的窦部及新窦部平均流速最高,作为参照(100%);随着TAVR撕裂或切除的瓣叶数量增加,平均流速从SAVR流量的25%升至70%。作者认为瓣叶撕裂可增强TAVR的窦部及新窦部流场,使其接近SAVR,可能对减少瓣叶血栓具有潜在临床意义。

要点

  • 在各条件下,SAVR的窦部及新窦部平均流速最高,用作TAVR条件的参照(100%)。
  • TAVR中随着撕裂或切除的瓣叶数量增加,平均窦部及新窦部流速从SAVR流量的25%升至70%。
  • 瓣叶撕裂显著增强了舒张期流速;即使完全切除瓣叶,SAVR较短的支架仍比TAVR较长的支架产生更高的流速。

核心结论

  • 瓣叶撕裂增强了TAVR的自身窦部及新窦部流场,使其接近SAVR。
  • 作者认为这些发现可能对使用单枚或多枚瓣叶撕裂来减少瓣叶血栓并因此可能改善TAVR耐久性具有潜在临床意义。

研究设计与样本

  • 体外研究,在已验证的模拟血流环路中于生理条件下比较SAVR与TAVR伴或不伴主动脉瓣叶撕裂的流速和流型。
  • 研究两种瓣膜:23-mm Perimount和26-mm SAPIEN 3(Edwards Lifesciences)。
  • 使用粒子图像测速技术在左冠瓣和无冠瓣定量新窦和自身窦的流体力学,并逐渐增加撕裂或切除的主动脉瓣叶数量。

主要发现

  • 在所有条件下,SAVR的窦部及新窦部平均流速最高,该值用作与TAVR条件比较的参照(100%)。
  • TAVR中随着撕裂或切除的瓣叶数量增加,平均窦部及新窦部流速从SAVR流量的25%升至70%。
  • 瓣叶撕裂显著增强了舒张期流速。
  • 即使完全切除瓣叶后,SAVR较短的支架相比TAVR较长的支架仍导致更高的流速。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Leaflet thrombosis after surgical aortic valve replacement (SAVR) and transcatheter aortic valve replacement (TAVR) may be caused by blood flow stagnation in the native and neosinus regions. To date, aortic leaflet laceration has been used to mitigate coronary obstruction following TAVR; however, its influence on the fluid mechanics of the native and neosinus regions is poorly understood. This in vitro study compared the flow velocities and flow patterns in the setting of SAVR vs TAVR with and without aortic leaflet lacerations. METHODS: Two valves, (23-mm Perimount and 26-mm SAPIEN 3; Edwards Lifesciences) were studied in a validated mock flow loop under physiologic conditions. Neosinus and native sinus fluid mechanics were quantified using particle image velocimetry in the left and noncoronary cusp, with an increasing number of aortic leaflets lacerated or removed. RESULTS: Across all conditions, SAVR had the highest average sinus and neosinus velocities, and this value was used as a reference to compare against the TAVR conditions. With an increasing number of leaflets lacerated or removed with TAVR, the average sinus and neosinus velocities increased from 25% to 70% of SAVR flow (100%). Diastolic velocities were substantially augmented by leaflet laceration. Also, the shorter frame of the SAVR led to higher flow velocities compared with the longer frame of the TAVR, even after complete leaflet removal. CONCLUSIONS: Leaflet laceration augmented TAVR native and neosinus flow fields, approaching that of SAVR. These findings may have potential clinical implications for the use of single or multiple leaflet lacerations to reduce leaflet thrombosis and thus potentially improve TAVR durability.

来源:J Thorac Cardiovasc Surg,查看原文。版权归原作者所有。

引用

  1. Sadri V, Kohli K, Ncho B, et al. Effect of leaflet laceration on transcatheter aortic valve replacement fluid mechanics and comparison with surgical aortic valve replacement. J Thorac Cardiovasc Surg. 2023. PMID: 37086238. doi:10.1016/j.jtcvs.2023.03.006

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。