Commando双瓣膜重建术后的解剖学考量:对未来瓣中瓣治疗的启示
本研究纳入2018年1月至2022年4月间接受Commando技术双瓣膜手术并有术后CT的7例患者,利用3mensio软件重建主动脉瓣和二尖瓣并模拟经导管瓣膜置换。结果显示重建后主动脉瓣-二尖瓣长度与角度大致呈反比,2例有术前影像者术后角度和幕长度显著改变,所有患者经导管主动脉瓣和二尖瓣置换均可行。
要点
- Commando术后主动脉瓣-二尖瓣长度与角度大致呈反比。
- 2例有术前CT者术后主动脉瓣-二尖瓣角度和幕长度显著改变。
- 所有患者术后经导管主动脉瓣和二尖瓣置换均可行。
核心结论
- 由主动脉瓣环缝线位置决定的主动脉瓣-二尖瓣幕长度可能是Commando术后瓣中瓣手术决策的重要考量。
研究设计与样本
- 回顾性分析2018年1月至2022年4月接受Commando技术双瓣膜手术并有术后CT的7例患者。
- 使用3mensio软件重建主动脉瓣和二尖瓣并模拟经导管瓣膜置换。
- 对2例有术前影像的患者分析重建导致的主动脉瓣-二尖瓣几何变化。
主要发现
- 重建后主动脉瓣-二尖瓣长度与主动脉瓣-二尖瓣角度大致呈反比。
- 2例有术前和术后CT的患者术后主动脉瓣-二尖瓣角度和主动脉瓣-二尖瓣幕长度显著改变。
- 所有患者Commando术后经导管主动脉瓣和二尖瓣置换均可行。
- 主动脉瓣-二尖瓣幕较短的患者主动脉瓣-二尖瓣角度较大,对二尖瓣瓣中瓣更有利。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: The Commando technique for reconstruction of the aortomitral intervalvular fibrous body is effective to facilitate double valve surgery in cases of endocarditis or infiltrative calcification. The length of patch utilized in reconstruction of the intervalvular fibrous body has an important relationship to the geometry of the mitral valve (MV) and aortic valve (AV) and may impact on potential future valve-in-valve (VIV) therapy. Here we report anatomic measurements after Commando reconstruction in a small group of patients and analyse the impact of reconstruction techniques on transcatheter VIV therapies. METHODS: Seven patients from January 2018 to April 2022 who underwent double valve surgery with the Commando technique with postoperative computed tomography (CT) scans were identified. Computed tomographic reconstruction of the AV and MV was performed using 3mensio software and virtual transcatheter valve replacement was performed. Two of these patients who had preoperative imaging was analysed to assess the change in aortomitral geometry resulting from reconstruction. RESULTS: Measurements for each patient post-reconstruction are given in the table. Aortomitral length was grossly inversely proportional to aortomitral angle (AMA). AMA and aortomitral curtain (AMC) length were significantly altered post-Commando in 2 analysed patients with pre- and postoperative computed tomography scan. Transcatheter AV and MV replacements were feasible in all patients post-Commando. The AMA was larger and more favorable for mitral VIV in patients in which the AMC was short. CONCLUSIONS: AMC length, as determined by location of AV annular sutures, may be an important consideration in surgical decision-making for VIV after the Commando procedure.
引用
- Simpson MT, Kachel M, Mirza F, et al. Anatomic considerations after commando double valve reconstruction: insights for future valve-in-valve therapies. Eur J Cardiothorac Surg. 2023. PMID: 37067485. doi:10.1093/ejcts/ezad155
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。