定量血流分数与冠状动脉旁路移植术后移植物结局:一项回顾性研究
本研究基于PATENCY试验2017至2019年接受冠状动脉旁路移植术的患者,回顾性计算目标血管定量血流分数(QFR),以12个月CT血管造影评估移植物闭塞。QFR>0.80组动脉移植物12个月闭塞风险显著高于QFR≤0.80组(7.1% vs 2.6%;P=.001),静脉移植物则无显著关联。
要点
- 目标血管QFR>0.80与动脉移植物12个月闭塞风险显著升高相关(7.1% vs 2.6%;P=.001)。
- 静脉移植物中QFR>0.80与≤0.80组12个月闭塞率无显著差异(4.6% vs 4.3%;P=.67)。
- 以QFR阈值0.78和0.75进行的敏感性分析结果稳定。
核心结论
- 目标血管QFR>0.80与冠状动脉旁路移植术后12个月动脉移植物闭塞风险显著升高相关,而目标病变QFR与静脉移植物闭塞无显著关联。
主要发现
- 动脉移植物中,QFR>0.80组12个月闭塞率7.1% vs QFR≤0.80组2.6%(P=.001;未调整模型OR 3.08,95%CI 1.65-5.75;完全调整模型OR 2.67,95%CI 1.44-4.97)。
- 静脉移植物中,QFR>0.80组12个月闭塞率4.6% vs QFR≤0.80组4.3%(P=.67;未调整模型OR 1.10,95%CI 0.82-1.47;完全调整模型OR 1.12,95%CI 0.83-1.51)。
- 以QFR阈值0.78和0.75进行的敏感性分析结果稳定。
关键数值与推荐
- QFR计算在符合条件的冠状动脉中进行,定义为狭窄≥50%且直径≥1.5 mm的血管。
- QFR≤0.80被视为功能性显著狭窄的阈值。
- 主要结局为12个月时通过计算机断层血管造影评估的移植物闭塞。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Quantitative flow ratio (QFR) is a novel noninvasive tool for the functional assessment of coronary stenosis. Whether or not QFR could predict graft outcomes after coronary artery bypass grafting procedure is unknown. This study aimed to investigate the association of QFR value with graft outcomes after coronary artery bypass grafting surgery. METHODS: The QFR values were retrospectively obtained from patients receiving coronary artery bypass grafting surgery from 2017 to 2019 in the Graft Patency Between No-Touch Vein Harvesting Technique and Conventional Approach in Coronary Artery Bypass Graft Surgery (PATENCY) trial. QFR calculation was conducted in eligible coronary arteries, defined as those with ≥50% stenosis and a diameter ≥1.5 mm. A threshold of QFR ≤0.80 was considered functionally significant stenosis. The primary outcome was graft occlusion at 12 months evaluated by computed tomography angiography. RESULTS: Two thousand twenty-four patients with 7432 grafts (2307 arterial grafts and 5125 vein grafts) were included. For the arterial grafts, the risk of 12-month occlusion was significantly increased in the QFR >0.80 group than in the QFR ≤0.80 group (7.1% vs 2.6%; P = .001; unadjusted model: odds ratio, 3.08; 95% CI, 1.65-5.75; fully adjusted model: odds ratio, 2.67; 95% CI, 1.44-4.97). No significant association was observed in the vein grafts (4.6% vs 4.3%; P = .67; unadjusted model: odds ratio, 1.10; 95% CI, 0.82-1.47; fully adjusted model: odds ratio, 1.12; 95% CI, 0.83-1.51). Results were stable across sensitivity analyses with a QFR threshold of 0.78 and 0.75. CONCLUSIONS: Target vessel QFR >0.80 was associated with a significantly higher risk of arterial graft occlusion at 12 months after coronary artery bypass grafting surgery. No significant association was found between target lesion QFR and vein graft occlusion.
引用
- Tian M, Xu B, Chen L, et al. Quantitative flow ratio and graft outcomes of coronary artery bypass grafting surgery: A retrospective study. J Thorac Cardiovasc Surg. 2023. PMID: 37084819. doi:10.1016/j.jtcvs.2023.04.011
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。