文献速递主动脉外科

A型主动脉夹层腔内修复:现有支架移植物及用于Endo-Bentall手术的瓣膜承载装置解剖适用性评估

Endovascular repair in type A aortic dissection: Anatomical candidacy for currently manufactured stent grafts and conceptual valve-carrying devices for an Endo-Bentall procedure.
PubMed 文献 · Eur J Cardiothorac Surg · 2023-01-01

该回顾性单中心队列研究纳入2009至2018年间112例A型主动脉夹层患者,基于CT评估6种市售支架移植物及2种瓣膜承载装置的解剖适用性。市售支架移植物解剖可行性为4%至21%,主要受限因素为近端锚定区直径、长度及破口距窦管交界过近;瓣膜承载装置解剖可行性为31%至80%,主要受限因素为主动脉瓣环直径及其与冠状动脉的距离。

要点

  • 市售支架移植物治疗A型主动脉夹层的解剖可行性仅4%至21%。
  • 主要限制为近端锚定区直径、扩张导致的长度不足及破口距窦管交界过近。
  • 瓣膜承载装置解剖可行性为31%至80%,主要限制为瓣环直径及与冠状动脉距离。

核心结论

  • 现有市售支架移植物治疗A型主动脉夹层的解剖适用性有限,主要因升主动脉缺乏合适近端锚定区;采用瓣膜承载装置经冠状动脉开窗或分支锚定于主动脉瓣环可能大幅改善适用性。

研究设计与样本

  • 回顾性单中心队列研究,纳入2009至2018年间200例升主动脉/主动脉弓手术中的112例A型主动脉夹层患者,基于CT评估6种市售支架移植物及2种瓣膜承载装置的解剖适用性。

主要发现

  • 市售支架移植物的解剖可行性范围为4%至21%。
  • 主要限制因素为近端锚定区直径(考虑过度尺寸<15%)、扩张导致的长度不足及破口距窦管交界过近。
  • 瓣膜承载装置的解剖可行性为31%至80%,主要限制因素为主动脉瓣环直径及其与冠状动脉的距离。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Endovascular treatment has been suggested as an alternative for open surgery for type A aortic dissection, but current devices have severe anatomical limitations. This study assesses the computed tomography-based anatomical suitability of currently manufactured stent grafts as well as 2 embodiments of valve-carrying devices. METHODS: In a retrospective single-centre cohort of 200 consecutive ascending/arch operations between 2009 and 2018, a total of 112 patients with type A aortic dissections were identified and evaluated for endovascular candidacy based on the locations of the entries, the landing zone diameters/lengths and the supra-aortic vessel origins according to the anatomical instructions for use criteria of 6 commercially available (tubular, branched or fenestrated) stent grafts. Two suggested valve-carrying devices with inner branches or fenestrations for the coronary arteries and branches for the supra-aortic vessels were also evaluated. RESULTS: The anatomical feasibility for commercial stent grafts ranged from 4% to 21%. The main limitations were proximal landing zone diameter (considering oversizing <15%), length due to dilatation and an entry too close to the sinotubular junction. For the valve-carrying conduits, anatomical feasibility was between 31% and 80%, with the main limiting factors being the diameter of the aortic annulus and its distance to the coronary arteries. CONCLUSIONS: The anatomical applicability of currently manufactured stent grafts for the treatment of type A aortic dissection is limited mainly by the absence of a suitable proximal landing zone in the ascending aorta and might substantially be improved by anchoring in the aortic annulus using a valve-carrying device that uses either fenestrations or branches for the coronary arteries.

来源:Eur J Cardiothorac Surg,查看原文。版权归原作者所有。

引用

  1. Kern M, Hauck SR, Dachs TM, et al. Endovascular repair in type A aortic dissection: Anatomical candidacy for currently manufactured stent grafts and conceptual valve-carrying devices for an Endo-Bentall procedure. Eur J Cardiothorac Surg. 2023. PMID: 36916747. doi:10.1093/ejcts/ezad085

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。