微创二尖瓣手术的质量改进项目:技术进展改善结局与手术时间
该单中心研究纳入2001至2020年间接受视频辅助或完全内镜微创二尖瓣手术的1000例患者,评估时代与技术改进对围术期结局的影响。结果显示围术期生存率99.1%,围术期成功率93.5%,围术期安全性96.3%;技术改进与手术成功率提高及手术时间缩短相关。
要点
- 围术期生存率99.1%,围术期成功率93.5%,围术期安全性96.3%。
- 3D可视化改善主动脉阻断时间(P=0.001),但不影响体外循环时间。
- 预测量人工腱索和术前CT扫描均不影响围术期成功率或安全性,但改善体外循环和主动脉阻断时间(均P<0.001)。
核心结论
- 手术经验增加提高微创二尖瓣手术的安全性。
- 技术改进与微创二尖瓣手术患者手术成功率提高和手术时间缩短相关。
研究设计与样本
- 单中心研究,纳入2001年至2020年间接受视频辅助或完全内镜微创二尖瓣手术的1000例患者(平均年龄60.8±12.7岁,男性60.3%)。
- 观察期内引入三种技术模式:3D可视化、预测量人工腱索(PTFE环)和术前CT扫描,比较技术改进引入前后的结果。
主要发现
- 741例患者接受单纯二尖瓣手术,259例接受同期手术,包括三尖瓣修复208例、左心房消融145例和卵圆孔未闭或房间隔缺损(ASD)关闭172例。
- 病因学:退行性738例(73.8%),功能性101例(10.1%)。
- 900例患者(90%)接受二尖瓣修复,100例患者(10%)接受二尖瓣置换。
- 围术期生存率99.1%,围术期成功率93.5%,围术期安全性96.3%。
- 围术期安全性改善归因于术后低心排血量发生率降低(P=0.025)和因出血再手术减少(P<0.001)。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Minimally invasive mitral valve surgery (MIMVS) has evolved over the last 2 decades. The aim of the study was to identify the impact of era and technical improvements on perioperative outcome after MIMVS. METHODS: A tota of 1000 patients (mean age: 60.8 ± 12.7 years, 60.3% male) underwent video-assisted or totally endoscopic MIMVS between 2001 and 2020 in a single institution. Three technical modalities were introduced during the observed period: (i) 3D visualization, (ii) use of premeasured artificial chordae (PTFE loops) and (iii) preoperative CT scans. Comparisons were made before and after the introduction of technical improvements. RESULTS: A total of 741 patients underwent isolated mitral valve (MV) procedure, whereas 259 received concomitant procedures. These consisted of tricuspid valve repair (208), left atrium ablation (145) and persistent foramen ovale or atrial septum defect (ASD) closure (172). The aetiology was degenerative in 738 (73.8%) patients and functional in 101 patients (10.1%). A total of 900 patients received MV repair (90%), and 100 patients (10%) underwent MV replacement. Perioperative survival was 99.1%, and periprocedural success 93.5% with a periprocedural safety of 96.3%. Improvement in periprocedural safety attributed to the lower rates of postoperative low output (P = 0.025) and less reoperations for bleeding (P < 0.001). 3D visualization improved cross-clamp (P = 0.001) but not cardiopulmonary bypass times. The use of loops and preoperative CT scan both had no impact on periprocedural success or safety but improved cardiopulmonary bypass and cross-clamp times (both P < 0.001). CONCLUSIONS: Increased surgical experience improves safety in MIMVS. Technical improvements are related to increased operative success and decreased operative times in patients undergoing MIMVS.
引用
- Gollmann-Tepeköylü C, Nägele F, Höfer D, et al. A qualitative improvement program for minimally invasive mitral surgery: technical advancements ameliorate outcome and operative times. Interdiscip Cardiovasc Thorac Surg. 2023. PMID: 36866493. doi:10.1093/icvts/ivad030
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。