文献速递先天性心脏病外科瓣膜外科

手工聚四氟乙烯三叶瓣带瓣管道用于肺动脉瓣置换的临床结局

Clinical outcomes of handmade polytetrafluoroethylene trileaflet-valved conduit used for pulmonary valve replacement.
PubMed 文献 · Eur J Cardiothorac Surg · 2023-01-01

本研究回顾性分析2011年起单术者采用翻转法手工制作三叶瓣聚四氟乙烯带瓣管道行肺动脉瓣置换的10年病例系列,共55例患者,中位随访2.9年,多数为法洛四联症。结果显示10年生存率92.7%、免于再干预率98.0%,术后超声示肺动脉狭窄及反流程度轻度或以下者分别占92.2%和92.0%,磁共振示右心室容积显著减小但射血分数无显著变化。

要点

  • 55例患者中41例为法洛四联症,中位二次肺动脉瓣置换年龄15.6岁,中位随访2.9年。
  • 10年生存率92.7%,免于再干预率98.0%,无再次手术,1例最终行经导管肺动脉瓣置入。
  • 术后超声示肺动脉狭窄和反流轻度或以下者分别占92.2%和92.0%,磁共振示右心室容积显著减小。

核心结论

  • 本系列显示手工翻转法三叶瓣带瓣管道在患者中具有满意的长期功能,设计简单且可高效重复制作,无需复杂制造工艺。

研究设计与样本

  • 单术者回顾性病例系列,纳入2010年10月至2020年1月期间使用翻转法手工制作三叶瓣带瓣管道行肺动脉瓣置换的患者,共55例,中位随访2.9年。

主要发现

  • 55例患者中41例诊断为法洛四联症,这些患者在中位年龄15.6岁时接受二次肺动脉瓣置换。
  • 生存率为92.7%,最长随访10年;无再次手术,10年免于再干预率为98.0%。
  • 共4例死亡(3例院内、1例院外),1例患者最终接受经导管肺动脉瓣置入。
  • 术后超声示肺动脉狭窄程度轻度或以下者占92.2%,肺动脉反流程度轻度或以下者占92.0%。
  • 磁共振数据(n=25)显示右心室容积显著减小,但射血分数无显著变化。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To mitigate the shortage of homograft sources, the use of handmade trileaflet expanded polytetrafluoroethylene valves in pulmonary valve replacement has shown excellent results from multicentre studies conducted in Japan. However, world-wide data outside Japan are relatively insufficient. This study presents the long-term results of a single surgeon's use of flipped-back trileaflet method in a 10-year case series. METHODS: We have developed an efficient way to make a trileaflet-valved conduit utilizing flipped-back method for pulmonary valve replacement and have employed the technique since 2011. Retrospective data were studied between October 2010 and January 2020. Echocardiography, electrocardiogram, Pro-Brain Natriuretic Peptide and Magnetic Resonance Imaging data were analysed. RESULTS: Fifty-five patients were reviewed and median follow-up duration was 2.9 years. The majority of diagnoses was Tetralogy of Fallot (n = 41), and these patients subsequently underwent secondary pulmonary valve replacement at a median age of 15.6 years. Survival was 92.7% with the longest follow-up period being 10 years. There was no need for reoperation, and freedom from reintervention was 98.0% at 10 years. There were 4 deaths (3 in-hospital and 1 outpatient). One patient eventually received transcatheter pulmonary valve implantation. Postoperative echocardiography showed mild or less pulmonary stenosis and pulmonary regurgitation degree in 92.2% and 92.0% of patients, respectively. Comparable magnetic resonance imaging data (n = 25) showed significant reduction in right ventricular volumes but not in ejection fractions. CONCLUSIONS: Our series showed satisfactory long-term function of handmade flipped-back trileaflet-valved conduit used in our patients. The simple design is efficiently reproducible without complex fabrication process.

来源:Eur J Cardiothorac Surg,查看原文。版权归原作者所有。

引用

  1. Chang TI, Hsu KH, Hung WL, et al. Clinical outcomes of handmade polytetrafluoroethylene trileaflet-valved conduit used for pulmonary valve replacement. Eur J Cardiothorac Surg. 2023. PMID: 36971610. doi:10.1093/ejcts/ezad120

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。