基于磁共振成像的血流动力学壁面剪切应力改变二叶式主动脉瓣患者的主动脉壁组织生物力学
研究对22例接受预防性主动脉根部/升主动脉置换的二叶式主动脉瓣患者行术前四维血流磁共振成像,用年龄匹配健康图谱(60例对照)定位局部壁面剪切应力(WSS)升高区域,采集78份组织样本按WSS(升高 vs 正常)和采集区域分类行平面双轴测试,线性混合效应模型显示高WSS与环向和轴向低拉伸切线模量升高相关,且独立于组织采集区域。
要点
- 高WSS与环向和轴向低拉伸切线模量(LTM)升高相关,独立于组织采集区域。
- 高WSS与环向非线性过渡区起点(TZo)和高拉伸切线模量(HTM)升高相关。
- 组织采集区域与轴向TZo、环向HTM和轴向HTM的变异相关。
核心结论
- 二叶式主动脉瓣主动脉病变患者的主动脉生物力学改变与血流动力学强相关,而非组织采集区域。
- 高WSS与低拉伸范围(即LTM和TZo)的组织行为相关。
研究设计与样本
- 对22例接受预防性主动脉根部和/或升主动脉置换的患者行术前四维血流磁共振成像,使用年龄匹配健康图谱(60例对照)识别局部WSS升高。
- 采集78份组织样本,按WSS(升高 vs 正常)和区域分类,行平面双轴测试,测量低拉伸线性区切线模量(LTM)、高拉伸线性区切线模量(HTM)及非线性过渡区起点(TZo)和终点应力。
- 采用线性混合效应模型确定统计学关系。
主要发现
- 环向和轴向LTM升高与WSS升高相关(分别为P = .007和P = .018),独立于采集区域。
- 环向TZo和HTM随WSS升高而升高(分别为P = .024和P = .003)。
- 采集区域与轴向TZo(P = .013)、环向HTM(P = .015)和轴向HTM(P = .001)的变异相关。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: In this study we aimed to conclusively determine whether altered aortic biomechanics are associated with wall shear stress (WSS) independent of region of tissue collection. Elevated WSS in the ascending aorta of patients with bicuspid aortic valve has been shown to contribute to local maladaptive aortic remodeling and might alter biomechanics. METHODS: Preoperative 4-dimensional flow magnetic resonance imaging was performed on 22 patients who underwent prophylactic aortic root and/or ascending aorta replacement. Localized elevated WSS was identified in patients using age-matched healthy atlases (n = 60 controls). Tissue samples (n = 78) were collected and categorized according to WSS (elevated vs normal) and region. Samples were subjected to planar biaxial testing. To fully quantify the nonlinear biomechanical response, the tangential modulus (local stiffness) at a low-stretch (LTM) and high-stretch (HTM) linear region and the onset (TZo) and end stress of the nonlinear transition zone were measured. A linear mixed effect models was implemented to determine statistical relationships. RESULTS: A higher LTM in the circumferential and axial direction was associated with elevated WSS (P = .007 and P = .018 respectively) independent of collection region. Circumferential TZo and HTM were higher with elevated WSS (P = .024 and P = .003); whereas the collection region was associated with variations in axial TZo (P = .013), circumferential HTM (P = .015), and axial HTM (P = .001). CONCLUSIONS: This study shows strong evidence that biomechanical changes in the aorta are strongly associated with hemodynamics, and not region of tissue collection for bicuspid valve aortopathy patients. Elevated WSS is associated with tissue behavior at low stretch ranges (ie, LTM and TZo).
引用
- Nightingale M, Scott MB, Sigaeva T, et al. Magnetic resonance imaging-based hemodynamic wall shear stress alters aortic wall tissue biomechanics in bicuspid aortic valve patients. J Thorac Cardiovasc Surg. 2023. PMID: 36797175. doi:10.1016/j.jtcvs.2022.12.021
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。