左心室辅助装置患者的心输出量评估方法:异方差性问题
本研究在61例左心室辅助装置(LVAD)患者中比较直接Fick法、热稀释法(TD)和间接Fick法(iFick)测定的心输出量(CO)。TD与LaFarge iFick和直接Fick呈中度相关,Dehmer和Bergstra iFick相关性差。所有方法均倾向于高估CO,在直接Fick CO最低者中高估最明显,TD的偏倚和异方差性最小。
要点
- 在LVAD患者中,TD与直接Fick CO呈中度相关(R²=0.49),LaFarge iFick次之(R²=0.38)。
- 所有CO估算方法均倾向于高估CO,在直接Fick CO最低的患者中高估最明显。
- TD的偏倚和显著差异频率最低,相关性略优于LaFarge iFick,异方差性更小。
核心结论
- 在LVAD患者中,TD和LaFarge iFick与直接Fick CO的相关性优于Dehmer和Bergstra iFick,但所有方法均存在显著偏倚并倾向于高估CO。
研究设计与样本
- 研究纳入61例LVAD患者,将直接Fick CO与热稀释法(TD)及间接Fick(iFick)CO进行比较。
主要发现
- TD与直接Fick的R²=0.49(p<0.001),LaFarge iFick的R²=0.38(p<0.001),Dehmer iFick的R²=0.29(p<0.001),Bergstra iFick的R²=0.31(p<0.001)。
- 所有CO估算方法与直接Fick CO的绝对偏倚均显著,其中TD的绝对偏倚最低。
- 所有方法均倾向于高估CO,在直接Fick CO最低的患者中高估最明显。
关键数值与推荐
- TD与直接Fick CO相关性中度(R²=0.49,p<0.001),LaFarge iFick中度(R²=0.38,p<0.001)。
- Dehmer iFick与直接Fick CO相关性差(R²=0.29,p<0.001),Bergstra iFick相关性差(R²=0.31,p<0.001)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Equipoise remains about how best to measure cardiac output (CO) in patients with left ventricular assist devices (LVAD). In this study, direct Fick CO was compared with thermodilution (TD) and indirect Fick (iFick) CO in 61 LVAD patients. TD and LaFarge iFick showed moderate correlation with direct Fick (R2 = 0.49 and R2 = 0.38, p < 0.001 for both), while Dehmer and Bergstra iFick showed poor correlation with direct Fick (R2 = 0.29 and R2 = 0.31, p < 0.001 for both). Absolute bias between all CO estimation techniques and direct Fick CO was lowest for TD compared to iFick methods but significant for all methods. All methods tended to overestimate CO compared to direct Fick, with greatest overestimation present in those with the lowest measured direct Fick CO. Bias and frequency of significant discrepancy were least using TD and Lafarge iFick CO estimation methods in this study, with TD CO demonstrating modestly better correlation and less heteroscedasticity compared to Lafarge.
引用
- Azih NI, Read JM, Jackson GR, et al. Cardiac output assessment methods in left ventricular assist device patients: A problem of heteroscedasticity. J Heart Lung Transplant. 2022. PMID: 36481112. doi:10.1016/j.healun.2022.10.021
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。