文献速递先天性心脏病外科

青少年Fontan患者静息及模拟运动时16-20毫米心外Goretex管道血流动力学表现

Haemodynamic performance of 16-20-mm extracardiac Goretex conduits in adolescent Fontan patients at rest and during simulated exercise.
PubMed 文献 · Eur J Cardiothorac Surg · 2022-01-01

本研究对51例置入16-20毫米心外管道的Fontan患者构建基于磁共振成像的个体化计算流体动力学模型,量化静息及模拟运动下的功率损失、压力阶差与标准化阻力。结果显示多数青少年患者管道相对偏小,导致血流动力学欠佳。

要点

  • 51例16-20毫米心外管道Fontan患者中,标准化管道平均横截面积较下腔静脉、上腔静脉、肝静脉及左右肺动脉小35-73%(均P<0.001)。
  • 静息时TCPC压力阶差中位数0.7 mmHg,模拟运动时2.0 mmHg。
  • 标准化平均管道横截面积与静息及运动下TCPC血流动力学呈中度至强度反向非线性关系。

核心结论

  • 16-20毫米心外管道在多数青少年Fontan患者中已相对偏小,导致血流动力学欠佳。

研究设计与样本

  • 对51例置入16-20毫米心外管道的Fontan患者,构建基于磁共振成像的个体化TCPC计算流体动力学模型。

主要发现

  • 患者中位年龄16.2岁(Q1-Q3 14.0-18.2)。
  • 标准化平均管道横截面积较下腔静脉、上腔静脉、肝静脉及左右肺动脉小35-73%(均P<0.001)。
  • TCPC压力阶差中位数静息时0.7 mmHg(Q1-Q3 0.5-0.8),模拟运动时2.0 mmHg(Q1-Q3 1.4-2.6)。
  • 标准化平均管道横截面积与静息及运动下TCPC血流动力学呈中度至强度反向非线性关系。
  • 管道横截面积≤45 mm2/l/min者静息TCPC压力阶差≥1.0 mmHg且模拟运动时≥3.0 mmHg;管道≥125 mm2/l/min者静息及运动下压力阶差均<1 mmHg。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To date, it is not known if 16-20-mm extracardiac conduits are outgrown during somatic growth from childhood to adolescence. This study aims to determine total cavopulmonary connection (TCPC) haemodynamics in adolescent Fontan patients at rest and during simulated exercise and to assess the relationship between conduit size and haemodynamics. METHODS: Patient-specific, magnetic resonance imaging-based computational fluid dynamic models of the TCPC were performed in 51 extracardiac Fontan patients with 16-20-mm conduits. Power loss, pressure gradient and normalized resistance were quantified in rest and during simulated exercise. The cross-sectional area (CSA) (mean and minimum) of the vessels of the TCPC was determined and normalized for flow rate (mm2/l/min). Peak (predicted) oxygen uptake was assessed. RESULTS: The median age was 16.2 years (Q1-Q3 14.0-18.2). The normalized mean conduit CSA was 35-73% smaller compared to the inferior and superior vena cava, hepatic veins and left/right pulmonary artery (all P < 0.001). The median TCPC pressure gradient was 0.7 mmHg (Q1-Q3 0.5-0.8) and 2.0 (Q1-Q3 1.4-2.6) during rest and simulated exercise, respectively. A moderate-strong inverse non-linear relationship was present between normalized mean conduit CSA and TCPC haemodynamics in rest and exercise. TCPC pressure gradients of ≥1.0 at rest and ≥3.0 mmHg during simulated exercise were observed in patients with a conduit CSA ≤ 45 mm2/l/min and favourable haemodynamics (<1 mmHg during both rest and exercise) in conduits ≥125 mm2/l/min. Normalized TCPC resistance correlated with (predicted) peak oxygen uptake. CONCLUSIONS: Extracardiac conduits of 16-20 mm have become relatively undersized in most adolescent Fontan patients leading to suboptimal haemodynamics.

来源:Eur J Cardiothorac Surg,查看原文。版权归原作者所有。

引用

  1. Rijnberg FM, van 't Hul LC, Hazekamp MG, et al. Haemodynamic performance of 16-20-mm extracardiac Goretex conduits in adolescent Fontan patients at rest and during simulated exercise. Eur J Cardiothorac Surg. 2022. PMID: 36342204. doi:10.1093/ejcts/ezac522

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。