文献速递主动脉外科

18-氟脱氧葡萄糖正电子发射断层扫描在诊断主动脉人工血管感染中的应用:开放手术与腔内修复的差异

18-Fluorodeoxyglucose positron emission tomography in the diagnosis of prosthetic aortic graft infection: the difference between open and endovascular repair.
PubMed 文献 · Eur J Cardiothorac Surg · 2022-01-01

该研究回顾性分析2011至2022年间71例主动脉修复术后行18F-FDG PET/CT的患者,其中14例诊断为主动脉人工血管感染。感染组SUV max显著高于非感染组[均值8.64(标准差2.78)vs 3.40(标准差0.84);P < 0.01]。非感染移植物中,开放手术修复后早期SUV max较高,而腔内修复后保持较低水平。

要点

  • 感染组SUV max均值8.64(标准差2.78),非感染组3.40(标准差0.84),P < 0.01。
  • 腔内修复后SUV max早期即低且稳定,恒定cut-off值SUV max=4.5似乎合适。
  • 开放手术修复后SUV max早期较高,似乎可接受根据术后时间采用阶梯式cut-off值。

核心结论

  • 腔内主动脉修复后,恒定cut-off值「SUV max = 4.5」似乎适用于诊断移植物感染,因其术后早期即保持低且稳定;开放手术修复后,似乎可接受根据术后时间采用「阶梯式cut-off值」。

研究设计与样本

  • 回顾性研究,交叉核对医院PET/CT数据库(N = 14 490)与科室数据库,识别主动脉修复术后行18F-FDG PET/CT的患者,从病历提取数据,图像由2名核医学专家共识阅片并记录18F-FDG摄取增高及测量SUV max。
  • 2011至2022年间1112例主动脉修复患者中识别出71例,其中18例因疑似移植物感染行18F-FDG PET/CT,其余53例因其他目的(恶性肿瘤等)行检查;14例按主动脉人工血管感染治疗。

主要发现

  • 感染组SUV max显著高于非感染组[均值8.64(标准差2.78)vs 3.40(标准差0.84);P < 0.01]。
  • 非感染移植物中,开放手术修复后早期SUV max较高,而腔内修复后保持较低。

关键数值与推荐

  • 腔内修复后诊断移植物感染:恒定cut-off值SUV max = 4.5似乎合适。
  • 开放手术修复后:似乎可接受根据术后时间采用阶梯式cut-off值。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: 18-Fluorodeoxyglucose (18F-FDG) positron emission tomography (PET)/computed tomography (CT) has been reported as useful for diagnosing aortic graft infection. However, 18F-FDG uptake may depend upon various factors including open versus endovascular repair and time from surgery. We aimed to elucidate the factors influencing its uptake and the diagnostic value of 18F-FDG PET/CT after open and endovascular repair. METHODS: Hospital database of PET/CT (N = 14 490) and our departmental database were cross-checked to identify those who underwent 18F-FDG PET/CT after aortic repair. Patient's data were retrieved from the chart. Images were reviewed by 2 nuclear medicine specialists in consensus, and the presence of increased 18F-FDG uptake was recorded. The maximum standardized uptake value (SUV max) was measured. RESULTS: Among the 1112 patients who underwent aortic repair between 2011 and 2022, 71 patients were identified. Eighteen patients underwent 18F-FDG PET/CT for suspected graft infection and the remaining 53 patients for other purposes (malignancy, etc.). Fourteen patients were treated as aortic graft infection. They had significantly higher SUV max than those without graft infection [mean 8.64 (standard deviation 2.78) vs 3.40 (standard deviation 0.84); P < 0.01]. In the non-infected grafts, SUV max was higher early after open surgical repair, while it remained low after endovascular repair. CONCLUSIONS: After endovascular aortic repair, a constant cut-off value of 'SUV max = 4.5' seems appropriate for diagnosing graft infection, since it remains low and stable from the early postoperative period. After open surgical repair, it seems acceptable to have 'stepwise cut-off value' depending on the time from surgery.

来源:Eur J Cardiothorac Surg,查看原文。版权归原作者所有。

引用

  1. Tsuda K, Washiyama N, Takahashi D, et al. 18-Fluorodeoxyglucose positron emission tomography in the diagnosis of prosthetic aortic graft infection: the difference between open and endovascular repair. Eur J Cardiothorac Surg. 2022. PMID: 36394268. doi:10.1093/ejcts/ezac542

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。