本研究回顾了本中心2018年7月至2022年4月间接受几何环瓣环成形术行主动脉瓣修复的36例儿童及成人先天性心脏病患者,中位年龄17.4岁。修复后主动脉瓣反流平均分级显著降低,平均跨瓣压差无变化;随访期间免于再手术率97%(33/34),免于≥3+复发性主动脉瓣反流率94%(32/34)。作者认为几何环瓣环成形环有助于实现一致的主动脉瓣修复成功,即使在儿童及复杂先天性心脏病患者中围术期及随访结局也良好。

要点

  • 36例儿童及成人先天性心脏病患者接受几何环瓣环成形术行主动脉瓣修复,中位年龄17.4岁。
  • 修复后主动脉瓣反流平均分级显著降低,平均跨瓣压差无变化。
  • 随访期间免于再手术率97%(33/34),免于≥3+复发性主动脉瓣反流率94%(32/34)。

核心结论

  • 几何环瓣环成形环有助于实现一致的主动脉瓣修复成功,即使在儿童及复杂先天性心脏病患者中围术期及随访结局也良好。

研究设计与样本

  • 回顾性 review 了本中心所有接受几何环瓣环成形环置入行主动脉瓣修复的儿童及成人先天性心脏病患者,研究期间为2018年7月至2022年4月,共纳入36例受试者。

主要发现

  • 中位年龄17.4岁(范围8-30岁),其中21例小于18岁。
  • 最常见的主要诊断为新主动脉瓣关闭不全或新主动脉根扩张,以及先天性主动脉瓣狭窄伴二叶或功能性单叶主动脉瓣。
  • 34例手术成功者中,31例(91%)使用了额外的瓣膜修复技术,26例(76%)进行了额外的同期手术。
  • 手术死亡率为0%(0/33),主要并发症发生率为6%(2/33)。
  • 中位随访时间1.9年(最长3.8年),修复后主动脉瓣反流平均分级显著降低,平均跨瓣压差无变化。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Existing replacement options for the aortic valve have significant drawbacks, especially in children. A geometric annuloplasty ring can help to achieve consistently successful aortic valve repair, but only limited experience with use of this device has been reported in pediatric and congenital heart disease patients. METHODS: All pediatric and adult congenital patients at our institution who underwent aortic valve repair with placement of a geometric annuloplasty ring were reviewed. The study period spanned from July 2018 to April 2022. Hemodynamic outcomes were evaluated using transthoracic echocardiography. RESULTS: The study included 36 subjects. The median age was 17.4 years (range, 8-30 years). Twenty-one subjects were younger than age 18 years. The most common primary diagnoses were neoaortic valve insufficiency or neoaortic root dilation, and congenital aortic stenosis with bicuspid or functionally unicuspid aortic valve. Of the 34 subjects with procedural success, 31 (91%) had use of additional valve repair techniques and 26 (76%) had an additional concomitant procedure performed. Operative mortality was 0% (0/33), and major complication rate was 6% (2/33). The median follow-up time was 1.9 years (maximum, 3.8 years). The mean grade of aortic insufficiency was signific antly reduced after repair, with no change in mean gradients. Freedom from reoperation over the follow-up period was 97% (33/34), and freedom from ≥3+ recurrent aortic insufficiency was 94% (32/34). CONCLUSIONS: A geometric annuloplasty ring can be used to help achieve consistently successful aortic valve repair with excellent perioperative and follow-up outcomes, even in pediatric and complex congenital heart disease patients.