自体外膜覆盖法在主动脉手术中的中期表现
本研究开发了外膜覆盖法加固主动脉吻合口,并评估其中期形态学与临床结局。2009年5月至2020年4月共160例连续患者接受胸主动脉手术,其中84例成功应用覆盖技术。中期随访显示覆盖法吻合口形态稳定,无吻合口狭窄或假性动脉瘤形成,临床可接受。
要点
- 外膜覆盖法吻合口内径比与内翻法无显著差异,显著大于毛毡夹心法。
- 覆盖法近端和远端吻合口均无吻合口狭窄。
- 仅1例因远端假腔动脉瘤扩大需二次手术。
核心结论
- 本研究显示外膜覆盖技术具有中期稳定性,中期结局临床可接受。
- 在真性主动脉瘤或夹层病例中均未观察到吻合口狭窄或假性动脉瘤形成。
研究设计与样本
- 从切除的动脉瘤或夹层主动脉壁获取并制备外膜,采用外膜覆盖法进行主动脉修复。
- 中期随访时通过计算机断层扫描评估吻合口形态特征,比较覆盖法、内翻法和毛毡夹心法的差异。
- 对1例需二次手术的患者进行宏观评估。
- 2009年5月至2020年4月期间,160例连续患者(104例男性,56例女性;平均年龄68.6±11岁;范围39-88岁)接受胸主动脉手术。
- 覆盖技术成功应用于84例。
主要发现
- 覆盖法吻合口部位维持形态学外观,无任何临床并发症。
- 计算机断层扫描测量吻合口/移植物的内径比显示,覆盖法与内翻法无显著差异,且显著大于毛毡夹心法。
- 覆盖法近端或远端吻合口均无吻合口狭窄。
- 仅1例因远端假腔动脉瘤扩大需二次手术。
- 观察到近端覆盖的外膜平滑附着于自体管腔,宏观上与原始内膜无法区分。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: We developed an adventitial overlay method for reinforcing aortic anastomoses. This study evaluated the midterm morphologic and clinical outcomes of this method. METHODS: We harvested and prepared adventitia from a resected aneurysm or dissected aortic wall and performed aortic repair using the adventitial overlay method. At the midterm follow-up, we examined the differences between overlay, inversion, and felt sandwich methods by evaluating the morphologic features of the anastomosis on computed tomography scans. Moreover, we performed macroscopic evaluation of 1 patient who required a second operation. RESULTS: Between May 2009 and April 2020, 160 consecutive patients (104 men, 56 women; mean age, 68.6 ± 11 years; range, 39-88 years) underwent thoracic aortic surgery. The overlay technique was successfully performed in 84 cases. The anastomosis sites of the overlay method maintained their morphologic appearance without any clinical complications. The inner diameter ratio of anastomosis/graft was measured by computed tomography, which revealed that the overlay method was not significantly different from inversion and was significantly larger than the felt sandwich method. There was no anastomotic stenosis in the proximal or distal overlay anastomosis. Only 1 patient required a second operation for an enlarged aneurysm of the distal false lumen. We observed that the proximal overlaid adventitia was smoothly attached to the native lumen and was macroscopically indistinguishable from the original intima. CONCLUSIONS: This study showed the midterm stability of the overlay technique. The midterm outcome was clinically acceptable. No anastomotic stenosis or pseudoaneurysm formation in either the true aortic aneurysm or dissection cases was observed.
引用
- Okada T, Minato N, Zempo N, et al. Midterm Performance of the Autologous Adventitial Overlay Method in Aortic Surgery. Ann Thorac Surg. 2022. PMID: 36181775. doi:10.1016/j.athoracsur.2022.09.030
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。