文献速递心外重症与机械循环支持

闭塞性聚四氟乙烯流出道保护套对左心室辅助装置患者的影响

The effect of occlusive polytetrafluoroethylene outflow graft protectors in left ventricular assist device recipients.
PubMed 文献 · J Heart Lung Transplant · 2022-07-21

回顾性分析194例连续HVAD植入患者,其中102例使用PTFE流出道保护套。PTFE使用是血流梗阻的独立预测因素(HR 2.15,95%CI 1.03-4.48,p=.04),血流梗阻与死亡率增加独立相关(HR 3.43,95%CI 1.94-6.06,p<.0001),PTFE对生存的影响无统计学意义(HR 0.95,95%CI 0.60-1.48,p=.81)。结论认为PTFE流出道保护套与血流梗阻累积概率增加相关,后者对生存有不良影响,因此有害。

要点

  • PTFE流出道保护套使用是血流梗阻的独立预测因素(HR 2.15,95%CI 1.03-4.48,p=.04)。
  • PTFE组流出道狭窄累积发生率显著高于非PTFE组(Gray检验,p=.03)。
  • 血流梗阻与死亡率增加独立相关(HR 3.43,95%CI 1.94-6.06,p<.0001)。

核心结论

  • 左心室辅助装置患者使用PTFE流出道保护套与血流梗阻累积概率增加相关,血流梗阻对生存有不良影响,因此PTFE保护套有害。

研究设计与样本

  • 回顾性分析2006年3月至2021年1月期间连续植入HVAD(Medtronic Inc; Medtronic, Minneapolis, MN)的194例患者数据,其中102例使用PTFE保护套。

主要发现

  • 研究期间37例患者(19.1%)发生血流梗阻。
  • 多变量Cox回归分析中,PTFE使用是血流梗阻的独立预测因素(HR 2.15,95%CI 1.03-4.48,p=.04)。
  • 血流梗阻包括两种装置故障:11例(5.7%)发生流出道狭窄,31例(16.0%)发生泵血栓。
  • PTFE组流出道狭窄累积发生率显著高于非PTFE组(Gray检验,p=.03);PTFE组泵血栓累积发生率较高但无统计学意义(Gray检验,p=.06)。
  • 多变量Cox回归模型中,PTFE使用对生存的影响无统计学意义(HR 0.95,95%CI 0.60-1.48,p=.81),而血流梗阻发生与死亡率增加独立相关(HR 3.43,95%CI 1.94-6.06,p<.0001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The use of polytetrafluoroethylene (PTFE) material as a protective cover for left ventricular assist device (LVAD) outflow grafts (OG) is a common practice. However, it has descriptively been linked to the development of blood flow obstruction (BFO). METHODS: Patient data from 194 consecutive HVAD (Medtronic Inc; Medtronic, Minneapolis, MN) recipients implanted between March 2006 and January 2021 were retrospectively analyzed. PTFE covers were used in 102 patients. Study outcomes included the incidence of BFO and survival on LVAD support. RESULTS: Thirty-seven patients (19.1%) developed BFO during the study period. On a multivariable Cox regression analysis, PTFE use was an independent predictor for the development of BFO (HR 2.15, 95% CI 1.03-4.48, p = .04). BFO comprised of 2 types of device malfunction: eleven patients (5.7%) developed outflow graft stenosis (OGS), and 31 patients (16.0%) developed pump thrombosis (PT). There was a significantly higher cumulative incidence of OGS in patients with PTFE cover than in those without (Gray's test, p =.03). However, the observed higher cumulative incidence of PT in PTFE patients was non-significant (Gray's test, p =.06). In a multivariable Cox regression model, the effect of PTFE use on survival was non-significant (HR 0.95, 95% CI 0.60-1.48, p =.81), while the development of BFO was independently associated with increased mortality (HR 3.43, 95% CI 1.94-6.06, p < .0001). CONCLUSIONS: The use of PTFE OG cover in LVAD patients is associated with an increased cumulative probability of development of BFO, the latter adversely impacting survival and is therefore, harmful.

来源:J Heart Lung Transplant,查看原文。版权归原作者所有。

引用

  1. Dimitrov K, Kaider A, Granegger M, et al. The effect of occlusive polytetrafluoroethylene outflow graft protectors in left ventricular assist device recipients. J Heart Lung Transplant. 2022. PMID: 36137868. doi:10.1016/j.healun.2022.07.010

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。