文献速递肺外科

切除肺叶对术后肺功能预测的影响

Effect of resected lung lobe on the prediction of postoperative pulmonary function.
PubMed 文献 · Eur J Cardiothorac Surg · 2022-01-01

本研究回顾性纳入125例接受电视辅助胸腔镜肺叶切除术的患者,比较亚段计数法与三维CT容积测定法预测术后第1秒用力呼气容积(FEV1)的准确性指数。结果显示两种方法总体准确性无显著差异(0.94±0.12 vs 0.93±0.11,P=0.539),但切除肺叶显著影响亚段计数法的准确性(P<0.001),而不影响三维CT容积测定法(P=0.370)。结论认为三维CT容积测定法预测术后FEV1不受切除肺叶影响。

要点

  • 亚段计数法与三维CT容积测定法预测术后FEV1的准确性指数无显著差异(P=0.539)。
  • 切除肺叶显著影响亚段计数法的准确性指数(P<0.001),但不影响三维CT容积测定法(P=0.370)。
  • 亚段计数法的准确性指数与切除肺叶、叶间分离缝合器数量及间质性肺炎显著相关(均P<0.001)。

核心结论

  • 切除肺叶影响亚段计数法预测术后FEV1的准确性,但不影响三维CT容积测定法;三维CT容积测定法预测术后FEV1独立于切除肺叶。

研究设计与样本

  • 回顾性研究,纳入125例接受电视辅助胸腔镜肺叶切除术的患者,术前及术后3个月行肺功能检查。
  • 定义准确性指数为预测术后FEV1与实测术后FEV1的比值,比较亚段计数法与三维CT容积测定法的准确性指数,并分析影响准确性指数的因素。

主要发现

  • 亚段计数法的准确性指数为0.94±0.12,三维CT容积测定法为0.93±0.11(P=0.539)。
  • 不同切除肺叶间亚段计数法的准确性指数存在显著差异(P<0.001),三维CT容积测定法无显著差异(P=0.370)。
  • 切除肺叶、叶间分离缝合器数量及间质性肺炎与亚段计数法的准确性指数显著相关(均P<0.001)。
  • 缝合器数量及间质性肺炎与三维CT容积测定法的准确性指数显著相关(均P<0.001),切除肺叶不是显著因素(P=0.240)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: This study examined whether a resected lung lobe can affect the accuracy of postoperative forced expiratory volume in 1 s (FEV1) predicted using the subsegment counting method and three-dimensional computed tomography (3D-CT) volumetry. METHODS: Overall, 125 patients who underwent lobectomy through video-assisted thoracic surgery were enrolled in this retrospective study. Pulmonary function tests were performed preoperatively and postoperatively at 3 months. We defined the accuracy index as the ratio of predicted postoperative FEV1 to measured postoperative FEV1 and compared the accuracy index of the subsegment counting method and 3D-CT volumetry. Factors affecting the accuracy index were also examined. RESULTS: The accuracy index of the subsegment counting method was 0.94 ± 0.12, versus 0.93 ± 0.11 for 3D-CT volumetry (P = 0.539). There was a significant difference among the resected lobes in the accuracy index of the subsegment counting method (P < 0.001) but not in that of 3D-CT volumetry (P = 0.370). The resected lobe, the number of staples used for interlobar dissection and interstitial pneumonia were significantly associated with the accuracy index of the subsegment counting method (all P < 0.001). The number of staples and interstitial pneumonia were significantly associated with the accuracy index of 3D-CT volumetry (P < 0.001, respectively), whereas the resected lobe was not a significant factor (P = 0.240). CONCLUSIONS: The resected lobe affected the accuracy of the subsegment counting method but not that of 3D-CT volumetry. Furthermore, 3D-CT volumetry predicted postoperative FEV1 independent of the resected lobe.

来源:Eur J Cardiothorac Surg,查看原文。版权归原作者所有。

引用

  1. Shibazaki T, Mori S, Noda Y, et al. Effect of resected lung lobe on the prediction of postoperative pulmonary function. Eur J Cardiothorac Surg. 2022. PMID: 36171679. doi:10.1093/ejcts/ezac480

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。