冠状动脉旁路移植术中的导管选择与早期移植物失败:COMPASS冠状动脉旁路移植术研究的析因分析
该研究为COMPASS冠状动脉旁路移植术研究的析因分析,纳入22个国家83个中心的1068例患者共3480条移植物,分析术后1年CT血管造影诊断的移植物失败率。左乳内动脉失败率为6.4%,桡动脉为9.9%,大隐静脉为10.4%,右乳内动脉为26.8%;右乳内动脉失败率高于桡动脉和大隐静脉,调整比值比分别为2.69和2.07。
要点
- 左乳内动脉1年移植物失败率为6.4%,桡动脉为9.9%,大隐静脉为10.4%,右乳内动脉为26.8%。
- 右乳内动脉失败率高于桡动脉(调整OR 2.69,95%CI 1.30-5.57,P=.008)。
- 右乳内动脉失败率高于大隐静脉(调整OR 2.07,95%CI 1.33-3.21,P=.001)。
核心结论
- 在该国际试验数据集中,左乳内动脉和桡动脉的表现符合预期,而静脉移植物的表现更好;右乳内动脉的高失败率令人担忧,并强调需要全面评估右乳内动脉在冠状动脉旁路移植术中的通畅性和安全性。
研究设计与样本
- COMPASS冠状动脉旁路移植术研究的析因分析,涉及22个国家83个中心的患者,分析了1068例接受冠状动脉旁路移植术且有完整CT血管造影数据的患者的3480条移植物。
主要发现
- 左乳内动脉移植物失败率为6.4%(68/1068),桡动脉为9.9%(9/91),大隐静脉为10.4%(232/2239),右乳内动脉为26.8%(22/82)。
- 右乳内动脉的移植物失败率高于桡动脉(调整比值比2.69;95%置信区间1.30-5.57;P=.008)。
- 右乳内动脉的移植物失败率高于大隐静脉(调整比值比2.07;95%置信区间1.33-3.21;P=.001)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Relative rates of early graft failure and conduit selection in coronary artery bypass grafting (CABG) surgery remain controversial. Therefore, we sought to determine the incidence and determinants of graft failure of the left internal mammary artery (LIMA), radial artery, saphenous vein, and right internal mammary artery (RIMA) 1 year after CABG surgery. METHODS: A post hoc analysis of the Cardiovascular Outcomes for People Using Anticoagulation Strategies (COMPASS) CABG study, involving patients from 83 centers in 22 countries. We completed an analysis of 3480 grafts from 1068 patients who underwent CABG surgery with complete computed tomography angiography data. The primary outcome was graft failure as diagnosed by computed tomography angiography 1 year after surgery. RESULTS: Graft failure occurred in 6.4% (68/1068) for LIMA, 9.9% (9/91) for radial artery, 10.4% (232/2239) for saphenous vein, and 26.8% (22/82) for RIMA grafts. The RIMA had a greater rate of graft failure (26.8%) than radial artery (9.9%) and veins (10.4%) (adjusted odds ratio, 2.69; 95% confidence interval, 1.30-5.57; P = .008 and adjusted odds ratio, 2.07; 95% confidence interval, 1.33-3.21; P = .001, respectively). CONCLUSIONS: In this international trial dataset, LIMA and radial artery performed as expected, whereas vein grafts performed better. However, high rates of RIMA failure are worrisome and highlight the need for a thorough evaluation of the patency and safety of the RIMA in CABG surgery.
引用
- Alboom M, Browne A, Sheth T, et al. Conduit selection and early graft failure in coronary artery bypass surgery: A post hoc analysis of the Cardiovascular Outcomes for People Using Anticoagulation Strategies (COMPASS) coronary artery bypass grafting study. J Thorac Cardiovasc Surg. 2022. PMID: 35760616. doi:10.1016/j.jtcvs.2022.05.028
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。