50-69岁患者的外科主动脉瓣置换术:来自德国主动脉瓣注册研究(GARY)的见解
基于德国主动脉瓣注册研究,分析2011至2012年间3046例50-69岁行孤立外科主动脉瓣置换术患者的资料,并进行倾向评分匹配。匹配后610对患者中,生物瓣组与机械瓣组5年死亡率无显著差异(12.1% vs 9.2%,P=0.05),再手术/再干预率亦无差异(2.5% vs 2.0%,P=0.546),但机械瓣组5年卒中率显著更高(3.3% vs 1.5%,P=0.04)。
要点
- 匹配后生物瓣与机械瓣5年死亡率无显著差异(12.1% vs 9.2%,P=0.05)。
- 机械瓣组5年卒中率显著高于生物瓣组(3.3% vs 1.5%,P=0.04)。
- 再手术/再干预率两组无显著差异(2.5% vs 2.0%,P=0.546)。
核心结论
- 在倾向匹配队列中,生物瓣或机械瓣行主动脉瓣置换术的5年生存和再手术结果相似,但机械瓣组卒中率显著增加,这可能影响年轻患者机械瓣的选择。
研究设计与样本
- 数据来自德国主动脉瓣注册研究,分析了2011至2012年间3046例接受孤立外科主动脉瓣置换术的患者,并进行倾向评分匹配。
主要发现
- 总体队列中,生物瓣组女性比例更高(32.7% vs 28.4%),log EuroSCORE I更高(5.41% vs 4.26%)。
- 倾向匹配后(610对),5年随访死亡率生物瓣组12.1% vs 机械瓣组9.2%(P=0.05)。
- 倾向匹配后(610对),再手术/再干预率生物瓣组2.5% vs 机械瓣组2.0%(P=0.546)。
- 倾向匹配后(610对),5年随访卒中率机械瓣组3.3% vs 生物瓣组1.5%(P=0.04)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: The aim of this study was to analyse the outcome of patients between 50 and 69 years of age undergoing biological or mechanical aortic valve replacement. METHODS: Data were collected from the German Aortic Valve Registry. Data were analysed regarding baseline characteristics and outcome parameters such as 5-year survival, stroke and reintervention. RESULTS: In total. UNLABELLED: 3046 patients undergoing isolated surgical aortic valve replacement between 2011 and 2012 were investigated and a propensity score matching was performed. Within this period, 2239 patients received a biological prostheses, while 807 patients received a mechanical prosthesis. Mean age in the biological group was 63.07 (±5.11) and 57.34 (±4.67) in the mechanical group (standardized mean difference 1.172). In the overall cohort, there were more female patients in the biological group (32.7% vs 28.4%) and log EuroSCORE I was higher (5.41% vs 4.26%). After propensity matching (610 pairs), there was no difference in the mortality at 5-year follow-up (12.1% biological vs 9.2% mechanical P = 0.05) nor for reoperation/reintervention (2.5% biological vs 2.0% mechanical, P = 0.546). Patients undergoing mechanical aortic valve replacement suffered from a higher stroke rate 3.3% vs 1.5% (P = 0.04) at 5-year follow-up. CONCLUSIONS: Aortic valve replacement with biological or mechanical prostheses showed similar 5-year outcomes for survival and reoperation in a propensity-matched cohort, but significantly increased stroke rate after mechanical aortic valve replacement. This could influence the choice of a mechanical valve in younger patients.
引用
- Vogt F, Santarpino G, Fujita B, et al. Surgical aortic valve replacement in patients aged 50-69 years-insights from the German Aortic Valve Registry (GARY). Eur J Cardiothorac Surg. 2022. PMID: 35567484. doi:10.1093/ejcts/ezac286
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。