左心室辅助装置治疗患者日常生活活动中的氧摄取
本研究比较稳定期左心室辅助装置(LVAD)患者与匹配健康对照在8项预设日常生活活动中的氧耗(占峰值摄氧量百分比)及功能容量。15例LVAD患者与16例对照完成活动及6分钟步行试验、峰值摄氧量测定。LVAD患者各项活动氧耗占峰值摄氧量比例均高于对照,6分钟步行时使用96%±8%的峰值摄氧量。
要点
- LVAD患者完成8项日常生活活动时氧耗占峰值摄氧量比例均高于匹配健康对照(所有P<0.001)。
- LVAD患者峰值摄氧量为14.9±2.2 ml/kg/min,对照为39.6±7.7 ml/kg/min(P<0.001)。
- LVAD患者6分钟步行试验中使用96%±8%的峰值摄氧量。
核心结论
- 耐久性LVAD接受者进行日常生活活动时的氧摄取水平比匹配健康对照更接近其峰值心肺储备。
研究设计与样本
- 研究纳入15例稳定期LVAD患者与16例对照,按性别、年龄、BMI、吸烟状态和族裔匹配。
- 使用移动设备(K5,Cosmed,罗马,意大利)测量8项预设日常生活活动中的摄氧量。
- 以6分钟步行试验测试次极量功能容量,以峰值摄氧量测试极量功能容量。
主要发现
- 患者年龄61±10岁,均为男性,BMI 28±5 kg/m²,植入Heartmate 3者占60%(DT:60%)。
- 峰值摄氧量患者为14.9±2.2 ml/kg/min,对照为39.6±7.7 ml/kg/min(P<0.001)。
- 各活动氧耗占峰值摄氧量百分比(患者 vs 对照):穿背心和LVAD设备41±5% vs 21±4%,叠毛巾41±6% vs 22±5%,穿袜和鞋50±16% vs 24±5%,将瓶子放入橱柜45±12% vs 22±4%,铺床50±8% vs 23±4%,无额外负重上下楼梯66±10% vs 30±4%,携带额外负重上下楼梯65±10% vs 31±5%,扫地75±10% vs 39±12%(所有P<0.001)。
- 6分钟步行试验中LVAD患者使用96%±8%的峰值摄氧量。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: Oxygen consumption during activities of daily life (ADL) is not described in recipients of left ventricular assist device (LVAD). We aimed to investigate the relation between oxygen consumption during predefined ADLs and measures of functional capacity (FC) in stable-phase LVAD recipients. METHODS: LVADs and controls were matched on gender, age, BMI, smoking status, and ethnicity. VO2 was measured using mobile equipment (K5, Cosmed, Rome, Italy) while putting on vest and LVAD equipment(1), folding towels(2), putting on socks and shoes(3), putting bottles in a cupboard(4), making a bed(5), walking on stairs without(6) and with extra weight(7), and sweeping the floor(8). Submaximal FC was tested by means of 6 minute walk test (6MWT) and peak oxygen uptake (pVO2) to test maximal FC. RESULTS: Fifteen LVAD patients and 16 controls were included; Patients were 61 ± 10years, all males with BMI 28 ± 5kg/m2 and implanted with Heartmate 3 (DT: 60%). PVO2 was 14.9 ± 2.2 ml/kg/min in patients and 39.6 ± 7.7 in controls (p < 0.001). Oxygen consumption expressed as percent of pVO2 for each task in patients vs controls was (%): ADL1: 41 ± 5 vs 21 ± 4, ADL2: 41 ± 6 vs 22 ± 5 %, ADL3: 50 ± 16 vs 24 ± 5%, ADL4: 45 ± 12 vs 22 ± 4, ADL5: 50 ± 8 vs 23 ± 4, ADL6: 66 ± 10 vs 30 ± 4, ADL7: 65 ± 10 vs 31 ± 5, ADL8: 75 ± 10 vs 39 ± 12, (p < 0.001 for all). During 6MWT LVAD patients used 96% ± 8 % of their pVO2. CONCLUSION: Recipients of durable LVADs perform daily life activities at oxygen uptake levels much closer to their peak cardiopulmonary reserve than matched healthy controls.
引用
- Mirza KK, Bonne T, Nordsborg NB, et al. Oxygen Uptake During Activities of Daily Life in Patients Treated With a Left Ventricular Assist Device. J Heart Lung Transplant. 2022. PMID: 35400588. doi:10.1016/j.healun.2022.03.009
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。