文献速递肺外科

正电子发射断层扫描对普通型间质性肺炎肺癌淋巴结分期的诊断价值

Diagnostic Value of Nodal Staging of Lung Cancer With Usual Interstitial Pneumonia Using PET.
PubMed 文献 · Ann Thorac Surg · 2022-04-12

本研究回顾性评估了2016年11月至2018年6月在本机构接受术前CT和PET/CT及肺切除加纵隔淋巴结清扫的198例非小细胞肺癌患者,比较有无间质性肺炎(IP)患者PET/CT淋巴结分期的诊断效能。结果显示无IP患者灵敏度36%、特异度94%、准确率77%,IP患者分别为25%、89%、73%;IP患者中肺部有FDG摄取者灵敏度13%、特异度93%、准确率65%,无FDG摄取者分别为50%、86%、81%。结论认为IP患者PET/CT诊断效能低于无IP患者,且IP伴FDG摄取者淋巴结分期准确率进一步降低。

要点

  • 无IP患者PET/CT淋巴结分期灵敏度36%、特异度94%、准确率77%。
  • IP患者灵敏度25%、特异度89%、准确率73%,低于无IP患者。
  • IP伴肺部FDG摄取者灵敏度13%、特异度93%、准确率65%。

核心结论

  • IP患者PET/CT淋巴结分期的诊断效能低于无IP患者。
  • IP伴肺部FDG摄取的患者淋巴结分期准确率进一步降低。

研究设计与样本

  • 回顾性评估2016年11月至2018年6月在本机构接受术前CT和PET/CT及解剖性肺切除加纵隔淋巴结清扫的198例患者。
  • IP诊断基于CT上存在UIP或可能UIP pattern。
  • 比较有无IP及有无肺部18F-FDG摄取患者的PET/CT淋巴结分期诊断效能。

主要发现

  • 无IP患者淋巴结分期灵敏度36%、特异度94%、准确率77%。
  • IP患者灵敏度25%、特异度89%、准确率73%。
  • 49例IP患者中23例肺部有FDG摄取。
  • IP伴FDG摄取者灵敏度13%、特异度93%、准确率65%。
  • IP无FDG摄取者灵敏度50%、特异度86%、准确率81%。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Preoperative staging of lymph node metastasis in patients with usual interstitial pneumonia (UIP) and non-small cell lung cancer (NSCLC) is difficult because inflammation can lead to false-positive imaging findings and clinical upstaging. We aimed to evaluate the accuracy of computed tomography (CT) and positron emission tomography (PET)/CT in nodal staging of NSCLC in patients with and without UIP. METHODS: Between November 2016 and June 2018, 198 patients underwent both preoperative CT and PET/CT and anatomic lung resection with mediastinal nodal dissection at our institute. Diagnosis of interstitial pneumonia (IP) was based on the presence of UIP or probable UIP pattern on CT. We retrospectively evaluated the diagnostic performance of PET/CT in nodal staging of NSCLC in patients with and without IP, with or without 18F-fluorodeoxyglucose (FDG) uptake in the lung. RESULTS: The sensitivity, specificity, and accuracy for nodal staging were 36%, 94%, and 77%, respectively, in patients without IP and 25%, 89%, and 73%, respectively, in those with IP. Of 49 patients with IP, 23 had FDG uptake in the lung. The sensitivity, specificity, and accuracy were 13%, 93%, and 65%, respectively, in patients with IP with FDG uptake and 50%, 86%, and 81%, respectively, in those without FDG uptake. CONCLUSIONS: We showed that the diagnostic performance of PET/CT in patients with IP was lower than that in patients without IP. Furthermore, the accuracy of nodal staging in patients with NSCLC and IP with FDG uptake was further decreased.

来源:Ann Thorac Surg,查看原文。版权归原作者所有。

引用

  1. Nomura K, Fukui M, Hattori A, et al. Diagnostic Value of Nodal Staging of Lung Cancer With Usual Interstitial Pneumonia Using PET. Ann Thorac Surg. 2022. PMID: 35427565. doi:10.1016/j.athoracsur.2022.03.056

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。