急性主动脉夹层假腔中外膜厚度与继发性主动脉扩张的关系
本研究通过术中标本显微图像测量假腔外膜厚度(OMT),评估其对下游主动脉继发性扩张的影响。纳入2007至2016年129例DeBakey I型夹层假腔通畅患者,中位随访4.3年。结果显示主动脉直径增长率与OMT呈负相关,OMT 0.04-0.15 mm组主动脉相关事件风险显著高于0.32-0.51 mm组。
要点
- OMT中位数0.21 mm,范围0.04-0.51 mm,个体差异明显
- OMT最低三分位组第一年主动脉扩张速度显著快于后续及其他三分位组
- OMT 0.04-0.15 mm为全因死亡的独立变量
核心结论
- 在DeBakey I型主动脉夹层假腔通畅患者中,远端残余夹层主动脉的增长率与OMT呈负相关。
- OMT为0.04至0.15 mm的患者主动脉相关事件风险显著更高。
研究设计与样本
- 回顾性分析2007至2016年238例急性A型夹层手术患者中符合纳入标准的129例。
- 纳入标准:DeBakey I型夹层假腔通畅、全层主动脉壁组织病理检查、术后3个月以上至少1次随访CT。
- 平均每例患者获得5.1次扫描,中位随访4.3年。
主要发现
- OMT中位数0.21 mm,范围0.04-0.51 mm,变异较大。
- 主动脉直径增长率与OMT呈负相关,OMT最低三分位组第一年扩张显著快于后续且快于其他三分位组。
- 以死亡为竞争风险的多因素Fine-Gray分析显示OMT为主动脉相关事件的独立变量。
- OMT 0.04-0.15 mm组主动脉相关事件风险为0.32-0.51 mm组的3.54倍,OMT 0.16-0.31 mm组为1.56倍。
- 多因素Cox回归显示OMT 0.04-0.15 mm为全因死亡的独立变量。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: This study measured the outer media thickness (OMT) at the false lumen by using microscopic images of specimens collected intraoperatively and assessed the impact of OMT on secondary dilatation of the downstream aorta. METHODS: Of 238 patients undergoing surgical procedures for acute type A dissection between 2007 and 2016, 129 patients fulfilled the inclusion criteria for this study: DeBakey type I dissection with a patent false lumen, histopathologic examination of full-thickness aortic wall, and at least 1 follow-up computed tomographic scan at more than 3 months after surgical procedures. On average, 5.1 scans were obtained per patient, and median follow-up was 4.3 years. RESULTS: Considerable variation was observed in OMT (median, 0.21 mm; range, 0.04-0.51 mm). The aortic diameter growth rate was inversely correlated with the OMT, and in the lowest tertile of OMT the aortic diameter dilated significantly faster in the first year than later and faster than in the other tertiles. Multivariable Fine-Gray analysis, with death as the competing risk, identified OMT as an independent variable for aortic-related events. Patients with OMT of 0.04 to 0.15 mm had a 3.54-fold higher risk of aortic-related events and those with 0.16 to 0.31 mm had a 1.56-fold higher risk of aortic-related events than did patients with OMT of 0.32 to 0.51 mm. Multivariable Cox regression analyses revealed OMT of 0.04 to 0.15 mm as an independent variable for all-cause mortality. CONCLUSIONS: In patients with DeBakey type I aortic dissection with a patent false lumen, the growth rate of the distal residual dissecting aorta was inversely correlated with the OMT. The risk of aortic-related events was significantly higher in patients with OMT of 0.04 to 0.15 mm.
引用
- Kinoshita T, Asai T, Suzuki T, et al. Outer Media Thickness at False Lumen and Secondary Aortic Dilatation After Acute Aortic Dissection. Ann Thorac Surg. 2022. PMID: 35292257. doi:10.1016/j.athoracsur.2022.02.050
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。