一种潜在的未来Fontan术式改良:工程化心脏组织压力生成管的初步体外数据

A potential future Fontan modification: preliminary in vitro data of a pressure-generating tube from engineered heart tissue.
PubMed 文献 · Eur J Cardiothorac Surg · 2022-01-01

本研究旨在利用工程化心脏组织(EHT)构建可收缩的肺下新心室以主动驱动肺血流。将人诱导多能干细胞衍生心肌细胞嵌入纤维蛋白水凝胶中围绕硅胶管铸造成三维管状EHT(长1.8 cm、内径6 mm、壁厚约1 mm),在持续搏动流下培养23天。结果显示管状EHT在培养8-14天开始宏观搏动,23天时呈协调搏动模式,等容压力测量显示协调搏动波形成,平均频率77 ± 5次/分,平均压力0.2 mmHg。结论认为需进一步优化支持材料、流速和几何形状以产生足够压力支持定向搏动血流。

要点

  • 管状EHT在培养8-14天开始宏观搏动,23天时呈协调搏动模式。
  • 等容压力测量显示平均频率77 ± 5次/分,平均压力0.2 mmHg。
  • 组织学显示心肌细胞主要沿管壁内外曲率纵向排列,中心细胞密度较低。

核心结论

  • 由人诱导多能干细胞构建的简单管状收缩性EHT可形成同步搏动模式,但需进一步优化支持材料、流速和几何形状以产生足够压力支持定向搏动血流。

研究设计与样本

  • 体外研究:将人诱导多能干细胞衍生心肌细胞(0.9 ml,18 mio/ml)嵌入纤维蛋白水凝胶中围绕硅胶管铸造成三维管状EHT(长1.8 cm、内径6 mm、壁厚约1 mm),在持续搏动流下培养23天。

主要发现

  • 管状EHT在培养8-14天开始宏观搏动,整个培养期间大小和形状保持稳定。
  • 培养23天后管状EHT显示协调搏动模式,等容压力测量显示协调搏动波形成,平均频率77 ± 5次/分,平均压力0.2 mmHg。
  • 组织学分析显示心肌细胞主要沿管壁内外曲率分布,以纵向排列为主,管壁中心细胞密度较低。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Univentricular malformations are severe cardiac lesions with limited therapeutic options and a poor long-term outcome. The staged surgical palliation (Fontan principle) results in a circulation in which venous return is conducted to the pulmonary arteries via passive laminar flow. We aimed to generate a contractile subpulmonary neo-ventricle from engineered heart tissue (EHT) to drive pulmonary flow actively. METHODS: A three-dimensional tubular EHT (1.8-cm length, 6-mm inner diameter, ca. 1-mm wall thickness) was created by casting human-induced pluripotent stem cell-derived cardiomyocytes (0.9 ml, 18 mio/ml) embedded in a fibrin-based hydrogel around a silicone tube. EHTs were cultured under continuous, pulsatile flow through the silicone tube for 23 days. RESULTS: The constructs started to beat macroscopically at days 8-14 and remained stable in size and shape over the whole culture period. Tubular EHTs showed a coherent beating pattern after 23 days in culture, and isovolumetric pressure measurements demonstrated a coherent pulsatile wave formation with an average frequency of 77 ± 5 beats/min and an average pressure of 0.2 mmHg. Histological analysis revealed cardiomyocytes mainly localized along the inner and outer curvature of the tubular wall with mainly longitudinal alignment. Cell density in the center of the tubular wall was lower. CONCLUSIONS: A simple tube-shaped contractile EHT was generated from human-induced pluripotent stem cells and developed a synchronous beating pattern. Further steps need to focus on optimizing support materials, flow rates and geometry to obtain a construct that creates sufficient pressures to support a directed and pulsatile blood flow.

来源:Eur J Cardiothorac Surg,查看原文。版权归原作者所有。

引用

  1. Köhne M, Behrens CS, Stüdemann T, et al. A potential future Fontan modification: preliminary in vitro data of a pressure-generating tube from engineered heart tissue. Eur J Cardiothorac Surg. 2022. PMID: 35218664. doi:10.1093/ejcts/ezac111